background image

RS485 Star Card Manual V14 4Feb04.doc  Page 9/29 

  

 

Internal view showing optional protocol converter 

 

IMPORTANT NOTE. 

When using the protocol converter, ensure that the starcard is set for 4 wire 
telemetry using 

SW3/8 OFF

. RS485 data IN to 

MASTER RA/RB

 or BBV 

TELEMETRY IN with a TX1500 and data OUT to domes on 

STAR 

TRA/TRB

SW3

SW1

SW2

00007-3

J22

J15

J14

J16

SW1

SW2

02003

Protocol conversion card (02003)

fitted over headers J14, J15, J22.

Close up view of protocol

conversion card.

SW1

SW2

02003

LD1

LD2

LD3

LD1 = RS485 out
LD2 = RS485 in
LD3 = Checksum ERROR

SW3/8 OFF
to select 4 WIRE

SW2(1-6) Output Protol Selection

1      2       3       4      5       6

PROTOCOL

BAUD

OFF OFF OFF OFF OFF OFF

SELF TEST

9600,N,8,1

ON   OFF OFF OFF OFF OFF

DEBUG MODE

19200,N,8,1

OFF ON   OFF OFF OFF OFF

DENNARD 2050

9600,N,8,1

ON   ON   OFF OFF OFF OFF

MARK MERCER

9600,N,8,1

OFF OFF ON   OFF OFF OFF

VCL

9600,N,8,1

ON   OFF ON   OFF OFF OFF

PANASONIC 850

9600,N,8,1

OFF ON   ON   OFF OFF OFF

PANASONIC 850

19200,N,8,1

ON   ON   ON   OFF OFF OFF

BBV RS485

9600,N,8,1

OFF OFF OFF ON   OFF OFF

JVC TK-C676

9600,E,8,1

ON   OFF OFF ON   OFF OFF

BBV RX450/RX550

9600,N,8,1

OFF ON   OFF ON   OFF OFF

CHUGAI ZC-S122

9600,E,8,1

ON   ON   OFF ON   OFF OFF

MOLYNX

9600,E,8,1

OFF OFF ON   ON   OFF OFF

PELCO P

9600,N,8,1

ON   OFF ON   ON   OFF OFF

PELCO P

9600,O,8,1

OFF ON   ON   ON   OFF OFF

PELCO P

9600,E,8,1

ON   ON   ON   ON   OFF OFF

PELCO P

2400,N,8,1

OFF OFF OFF OFF ON   OFF

PELCO P

2400,O,8,1

ON   OFF OFF OFF ON   OFF

PELCO P

2400,E,8,1

OFF ON   OFF OFF ON   OFF

PELCO D

9600,N,8,1

ON   ON   OFF OFF ON   OFF

PELCO D

9600,O,8,1

OFF OFF ON   OFF ON   OFF

PELCO D

9600,E,8,1

ON   OFF ON   OFF ON   OFF

PELCO D

2400,N,8,1

OFF ON   ON   OFF ON   OFF

PELCO D

2400,O,8,1

ON   ON   ON   OFF ON   OFF

PELCO D

2400,E,8,1

OFF OFF OFF ON   ON   OFF

360 VISION

9600,N,8,1

ON   OFF OFF ON   ON   OFF

CHUGAI SMD20

9600,N,8,1

OFF ON   OFF ON   ON   OFF

VICON

9600,N,8,1

ON   ON   OFF ON   ON   OFF

VISTA POWERDOME

9600,N,8,1

OFF OFF ON   ON   ON   OFF

SAMSUNG SCC641/643

9600,N,8,1

ON  OFF  ON   ON   ON   OFF

MEYERTECH VICTA

9600,N,8,1

 Data IN

RA/RB

 Data OUT

TRA/TRB

SW2 Output Settings

1 2 3 4 5 6 7 8

RJ45 from

Tx1500

TELEMETRY

1 - 3 Protocol Selection

1

2

3

Protocol

OFF

OFF

OFF

BBV RS485
(TX1500)

ON

OFF

OFF

PELCO P

OFF

ON

OFF

PELCO D

ON

ON

OFF

VCL TP

4 - 5 Baud

4

5

Baud

OFF

OFF

2400

ON

OFF

4800

OFF

ON

9600

ON

ON

19200

6 - 7 Parity

6

7

Parity

OFF

OFF

NONE

ON

OFF

EVEN

OFF

ON

ODD

ON

ON

NONE

8 Data bits

OFF

8 BITS

ON

7 BITS

1 2 3 4 5 6 7 8

SW1 Input Settings

Summary of Contents for RS485 StarCard

Page 1: ...ional Telemetry Protocol Converter This manual covers software version CONV1_V14 Refer to addendum if using different software BBV RX450 550 CBC SMD20 Star MD2000 Sanyo VCC9200P Chugai Ganz ZC S122 12...

Page 2: ...eaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning Attachments Do not use attachments not recommended by the product manufacturer as they may cause hazards Water and M...

Page 3: ...l operation e If the unit has been dropped or the enclosure is damaged f If the unit exhibits a distinct change in performance This indicates a need for service Replacement Parts If replacement parts...

Page 4: ...e output protocol V12 10 Sept 2003 1 Added support for CBC SMD20 Star MD2000 Sanyo VCC9200P from BBV 2 Added support for Vicon Surveyor from BBV 3 VCL output protocol additional features added 4 Fix t...

Page 5: ...h either 2 wire half duplex or 4 wire full duplex systems It has been tested with the Panasonic FS616 multiplexer in 2 and 4 wire modes and with the SX350 video matrix in 2 wire mode The Star Card can...

Page 6: ...2 Output 5 termination SW2 3 2 4 Output 6 termination SW2 5 2 6 Output 7 termination SW2 7 2 8 Output 8 termination SW3 Option selection SW3 1 and SW3 2 RS485 input line termination ON termination ON...

Page 7: ...and dome receivers must be the same It is advisable to use 9600 baud to reduce the possibility of corrupted data causing intermittent control Panasonic Specific notes FS616 A single RS485 output is av...

Page 8: ...tes for the controller and dome receivers must be the same It is advisable to use 9600 baud to reduce the possibility of corrupted data causing intermittent control Panasonic Specific Notes FS616 A si...

Page 9: ...600 N 8 1 OFF ON OFF ON OFF OFF CHUGAI ZC S122 9600 E 8 1 ON ON OFF ON OFF OFF MOLYNX 9600 E 8 1 OFF OFF ON ON OFF OFF PELCO P 9600 N 8 1 ON OFF ON ON OFF OFF PELCO P 9600 O 8 1 OFF ON ON ON OFF OFF P...

Page 10: ...MARK MERCER V7 3 9600 N 8 1 A debug mode can also be selected which provides detailed information for each command received Whilst trouble shooting BBV engineers may ask you to use this mode with a la...

Page 11: ...is version of software Input Protocol Output Protocol BBV TX1500 PELCO D P VCL DENNARD 2050 X X MARK MERCER X X VCL TP X X PANASONIC CS850 860 X BBV RS485 RX457 557 X X JVC TKC676 X X BBV RX450 550 X...

Page 12: ...enu 3 GOTO PRESET 94 Start current dome s Sequence 001 1 PATROL GOTO PRESET 97 Start ALL DOMES Sequence 001 2 PATROL GOTO PRESET 98 Navigate through the dome menu using pan tilt and issue GOTO PRESET...

Page 13: ...if required Advanced Function TX1500 Procedure Manual 180 degree pan flip U turn 1 Program a privacy zone 2 followed by PROGRAM 1 28 PRESET Clear a privacy zone 3 followed by PROGRAM 1 28 PRESET Dome...

Page 14: ...1 high speed GOTO PRESET 97 max speed with 10 second dwell Start preset tour 2 slow speed GOTO PRESET 98 speed 32 with 10 second dwell Start Learned tour 5 GOTO PRESET 99 must be defined with SAVE PRE...

Page 15: ...t to 19200 N 8 1 with SW2 The dome must be set to Panasonic CONVENTIONAL protocol and the address set accordingly The 4 way dome switch must be set to 4 wire telemetry with switches 2 3 4 OFF The RS48...

Page 16: ...press 1 for the TX1500 or SAVE PRESET 95 with Pelco Addition functions Pressing AUTOPAN with a TX1500 or GOTO PRESET 99 with Pelco will cause the current dome to start an AUTOPAN Pressing 1 PATROL wit...

Page 17: ...are terminated by turning switch 8 ON and the intermediate domes have the switch 8 OFF A total of up to 96 domes are supported with a maximum of 32 domes per star output Menu access Press 1 will toggl...

Page 18: ...Starcard TRB Set the receiver address switches to match the number of the camera input of the TX1500 Molynx receivers can only be controlled when using BBV telemetry into the StarCard ie from the BBV...

Page 19: ...0 degree pan flip U turn 2 GOTO PRESET 33 Display Technicians Menu 3 GOTO PRESET 94 Start Random Scanning PATROL 1 GOTO PRESET 97 Start Frame Scanning PATROL 2 GOTO PRESET 98 This allows control of Pe...

Page 20: ...ET Clear a privacy zone 3 followed by PROGRAM 1 32 PRESET Add preset position to the tours Programming a preset position adds the preset into the tour 1 16 only Remove a preset from the tours PROGRAM...

Page 21: ...Tour definitions are compatible with the VCL programming method 2 including dwell time and speed per tour point The dome home feature can be programmed using the standard VCL control menu In addition...

Page 22: ...ould appear that the controller hasn t sent the command to the dome not the case ii The converter is limited to control ONE dome at a time because of this timing A lockout period prevents other camera...

Page 23: ...tionality is provided Manual pan tilt control with 16 speed steps Zoom with Manual Focus override Operating the Zoom will re enable auto focus after manual adjustment 64 preset positions 3 tours can b...

Page 24: ...diate domes have the RS485 de terminated The following functionality is provided Manual pan tilt control with 16 speed steps Zoom with Manual Focus override Operating the Zoom will re enable auto focu...

Page 25: ...the AUTOPAN key PRESET SCAN can be started using 1 PATROL PATTERN 2 can be started using 2 PATROL The patterns are defined from the dome menu which is accessed using 1 as below Advanced Function TX150...

Page 26: ...nality is provided Variable speed Pan Tilt 8 speeds Zoom Focus WASH WIPE LIGHTS auxiliary outputs 32 preset positions The Meyertech protocol supports 8 speeds for pan and tilt If the head is to pan an...

Page 27: ...g 1200M Maximum 1200M Maximum Star Card Star Card Star Card Control System On single direction RS485 multiple StarCards can be daisy chained to provide multiple outputs RS485 to domes receivers RS485...

Page 28: ...rate StarCard The diagram on the left shows a connection to port 2 Camera 1 DC Head Camera 2 AC Head Camera 3 DC Head Rx550 Address 1 Rx450 Address 2 Rx550 Address 3 Terminated Terminated Terminated T...

Page 29: ...N 1 2 3 4 5 6 7 8 ON SW1 Pelco D 2400 E 8 1 SW2 VCL 9600 N 8 1 Protocol converter switch settings for VCL conversion IMPORTANT Set each camera to Pelco Spectra II within the DVX setup then set the Sta...

Reviews: