RS485 Star Card Manual V14 4Feb04.doc Page 9/29
Internal view showing optional protocol converter
IMPORTANT NOTE.
When using the protocol converter, ensure that the starcard is set for 4 wire
telemetry using
SW3/8 OFF
. RS485 data IN to
MASTER RA/RB
or BBV
TELEMETRY IN with a TX1500 and data OUT to domes on
STAR
TRA/TRB
.
SW3
SW1
SW2
00007-3
J22
J15
J14
J16
SW1
SW2
02003
Protocol conversion card (02003)
fitted over headers J14, J15, J22.
Close up view of protocol
conversion card.
SW1
SW2
02003
LD1
LD2
LD3
LD1 = RS485 out
LD2 = RS485 in
LD3 = Checksum ERROR
SW3/8 OFF
to select 4 WIRE
SW2(1-6) Output Protol Selection
1 2 3 4 5 6
PROTOCOL
BAUD
OFF OFF OFF OFF OFF OFF
SELF TEST
9600,N,8,1
ON OFF OFF OFF OFF OFF
DEBUG MODE
19200,N,8,1
OFF ON OFF OFF OFF OFF
DENNARD 2050
9600,N,8,1
ON ON OFF OFF OFF OFF
MARK MERCER
9600,N,8,1
OFF OFF ON OFF OFF OFF
VCL
9600,N,8,1
ON OFF ON OFF OFF OFF
PANASONIC 850
9600,N,8,1
OFF ON ON OFF OFF OFF
PANASONIC 850
19200,N,8,1
ON ON ON OFF OFF OFF
BBV RS485
9600,N,8,1
OFF OFF OFF ON OFF OFF
JVC TK-C676
9600,E,8,1
ON OFF OFF ON OFF OFF
BBV RX450/RX550
9600,N,8,1
OFF ON OFF ON OFF OFF
CHUGAI ZC-S122
9600,E,8,1
ON ON OFF ON OFF OFF
MOLYNX
9600,E,8,1
OFF OFF ON ON OFF OFF
PELCO P
9600,N,8,1
ON OFF ON ON OFF OFF
PELCO P
9600,O,8,1
OFF ON ON ON OFF OFF
PELCO P
9600,E,8,1
ON ON ON ON OFF OFF
PELCO P
2400,N,8,1
OFF OFF OFF OFF ON OFF
PELCO P
2400,O,8,1
ON OFF OFF OFF ON OFF
PELCO P
2400,E,8,1
OFF ON OFF OFF ON OFF
PELCO D
9600,N,8,1
ON ON OFF OFF ON OFF
PELCO D
9600,O,8,1
OFF OFF ON OFF ON OFF
PELCO D
9600,E,8,1
ON OFF ON OFF ON OFF
PELCO D
2400,N,8,1
OFF ON ON OFF ON OFF
PELCO D
2400,O,8,1
ON ON ON OFF ON OFF
PELCO D
2400,E,8,1
OFF OFF OFF ON ON OFF
360 VISION
9600,N,8,1
ON OFF OFF ON ON OFF
CHUGAI SMD20
9600,N,8,1
OFF ON OFF ON ON OFF
VICON
9600,N,8,1
ON ON OFF ON ON OFF
VISTA POWERDOME
9600,N,8,1
OFF OFF ON ON ON OFF
SAMSUNG SCC641/643
9600,N,8,1
ON OFF ON ON ON OFF
MEYERTECH VICTA
9600,N,8,1
Data IN
RA/RB
Data OUT
TRA/TRB
SW2 Output Settings
1 2 3 4 5 6 7 8
RJ45 from
Tx1500
TELEMETRY
1 - 3 Protocol Selection
1
2
3
Protocol
OFF
OFF
OFF
BBV RS485
(TX1500)
ON
OFF
OFF
PELCO P
OFF
ON
OFF
PELCO D
ON
ON
OFF
VCL TP
4 - 5 Baud
4
5
Baud
OFF
OFF
2400
ON
OFF
4800
OFF
ON
9600
ON
ON
19200
6 - 7 Parity
6
7
Parity
OFF
OFF
NONE
ON
OFF
EVEN
OFF
ON
ODD
ON
ON
NONE
8 Data bits
OFF
8 BITS
ON
7 BITS
1 2 3 4 5 6 7 8
SW1 Input Settings