Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 83 of 252
Status: 19.03.2021
the other Slaves are assigned accordingly:
•
In our example:
Slave2: 2 buttons (Start) + 4 x Emergency-Stopt + 2 switches (b lamp)
Slave3: 1 button (Start) + 2 x Emergency-Stop + 2 switches (relays to interrupt other
functions)
For units with an encoder connection, also these encoder connections must be given. For ths
purpose, an encoder version can be selected f
rom the library in the “
Encoder folder.
•
Our example:
sine not connected).
The connections of the elements are also adopted and displayed in the terminal scheme:
Figure 62 Terminal scheme with elements
NOTICE:
Units marked in red still have elements that have not been used yet.
The elements marked in red in the right Library window have not been used yet.
NOTICE:
All available elements (marked in red) must be used / incorporated.
If elements are unused, the compilation creates an error in SafePLC with the according error
message.