IDS701 User Manual
Page 17 of 25
range
Overload range
01d
~
99d
remark
:
d is the setting graduation
(division)
Negative
display
C25
Negative display
Option
:
0=-9d
10=10% max. capacity
20=20% max. capacity
Standstill
setting
C26
Standstill time
option
:
0= quick
1= medium
2= slow
C27
Standstill range
option
:
1=1d
2=2d
5=5d
10=10d
Note: d=division
Digital filter
C28
Dynamic filter
Instruction
:
Dynamic filter is
collecting the data
filter before loaded
weight
stable.
When
loaded
weight
easily
shaking
(for
example animal) ,
you can set this
filter
to
make
weight
display
more stable
option
:
0= close dynamic filter
1=1 digital filter strength
2=2 digital filter strength
3=3 digital filter strength
4=4 digital filter strength
5=5 digital filter strength
6=6 digital filter strength
Note
:
Pls setting dynamic filter
strength carefully, the No. is
bigger, more stable. if the
loaded weight shake not too
much. The setting is less
than 3
Manual usuario BBG ref BULL