IDS701 User Manual
Page 9 of 25
At Zero mode, load weight till stable, Press
go to accumulating
Mode,” total” light on, display” n001”, and then display loaded weight;
unload weight , back to zero, load weight again till stable. Press
,
display”n002”
Then display the loaded weight. Repeat it maximum 999 times.
Check the total weight operation:
Press
and hold it then press
At the same time, display ”n**”, (accumulating times) then display total
weight.
There are 8 data totally. It shows the first 4 digital. then the last 4 digital
For example, the first
4 digital is”0012”, the last 4 digital is”34,56”
It means the actual weight is “1234.56”
At TOTAL (accumulate)mode, Press
display “ clr n”, it means don’t
clear the total Weight, Press
exit it; if clear total weight,
Press
“clr n” change to “clr y” it means clear total weight
display. Press
to clear the the total weight and exit accumulating mode.
3.6 Print function
When the data is stable, connection with printer, it will be printed after
press
“set”1 second.