  Determine the cable routing

   Break out the respective part of the cover if necessary

  

Punch hole into the grommet

…  or use holes 

in the base plate 

Break out … 

Hint:

or

3

Installation

DIP switch test input

ON

Low-active

1

ON

*

High-active

*

 = factory setting 

VIN

Test

Output 

Power supply 

(12–36 V

AC/DC)

4

Wiring

(Uth > 10 V AC/DC,

< 11 mA @ 36 V)

Only to be wired

in case of a

Cat. 2 application

Cable Ø: 3.1 – 5.2 mm

36 V  

1 A

Do not wire 

3/4 and 5/6

simultaneously

Note:

 When using the NC outputs (5/6) in Cat. 3 set-up, the wiring with the control must be permanently installed and protected against external 

damage according to EN ISO 13849-2 Tab.D.4 or else Cat. 2 applies and a test signal is needed.

Wire cross section 
0.25 – 0.75 mm

2

3.1  Cable routing, strain relief