background image

 

 

PM5-SA4 Converter 4-20mA – User Manual

 

3

 

4.

 

Unbolt the four screws of the lid of the connection 
terminal box and remove the lid. Take out the 
aluminium rail afterwards. 

 

 

 

5.

 

To close the casing, reverse this procedure. 

 

5.2

 

Insert the PM5-SA4 plug-in module 

 

1.

 

Use plug-in connector 1 (on the left) for the 
installation of the PM5-SA4 plug-in module. 

 

 

 
2.

 

Dismantle the cable (or cables) on the required 
length inside the casing and insert it (them) into the 
casing through one or more cable glands. 

 

 

 

 

IMPORTANT NOTICE! 

In order to minimize the influence of possible 
inductive  disturbances,  we  recommend  to 
use  cables  with  twisted  cable  pairs  for  each 
channel.

 

 
3.

 

Now connect the cable ends to the connection 
terminals of the PM5-SA4 plug-in module. The digits 
1 to 4 indicate the channel numbers which you can 
later select in the configuration menu. 

 

 

 

4.

 

Insert the PM5-SA4 plug-in module carefully into the 
plug-in connector 1 (on the left). 

 

 

HAZARD! 
Improper positioning 

Improper (inaccurate) positioning of the plug-
in  module  and  applying  too  strong  forces 
may  bent  or  even  break  the  contact  pins  of 
the plug-in connector. 

Potential  consequence: 

Irreparable  damage 

of the plug-in connector, need for factory 
repair service. 

Take  care  for  the  correct  and  accurate 
position  of  the  plug-in  module  and  do  not 
apply too strong forces.

 

 

 

 

Reviews: