PM5-REL-4 Relay Module – User Manual
3
4.
Unbolt the four screws of the lid of the connection
terminal box and remove the lid. Take out the
aluminium rail afterwards.
5.
To close the casing, reverse this procedure.
5.2
Insert the PM5-REL-4 plug-in module
1.
Each of the plug-in connectors 1 to 3 can be used for
the PM5-REL-4 plug-in module. For an optimal cable
route, we recommend to use plug-in connector 3 (on
the right)
2.
Dismantle the cable (or cables) on the required
length inside the casing and insert it (them) into the
casing through one or more cable glands.
3.
Now connect the cable ends to the connection
terminals of the PM5-REL-4 plug-in module.
OUT5..OUT8 identify the 4 relay switch outputs that
can later be selected in the menu. OUT5 and OUT6
are changeover switches as shown in the figure
below.
4.
Insert the PM5-REL-4 plug-in module carefully into
the plug-in connector 3 (on the right).
HAZARD!
Improper positioning
Improper (inaccurate) positioning of the plug-
in module and applying too strong forces
may bent or even break the contact pins of
the plug-in connector.
Potential consequence:
Irreparable damage
of the plug-in connector, need for factory
repair service.
Take care for the correct and accurate
position of the plug-in module and do not
apply too strong forces.