background image

1.

 

General safety instructions 

This operating manual contains basic instructions that must be 

complied with for installation, commissioning, operation, and 
maintenance. Consequently this operating manual must always 

be read by the fitter as well as the responsible owner prior to 
installation and commissioning, and must be accessible to 
every user of the device. In addition, all other safety 

instructions in this document must be strictly complied with. 
Read and comply with all instructions. 
To reduce the danger of injury, do not allow children to use this 

product. 
 

Dangers due to failure to comply with the safety 
instructions 

Failure to comply with the safety instructions can result in 

hazards for personnel as well as for the environment and the 
device.  
Failure to comply with the safety instructions can result in loss 

of all claims for damage compensation. 
 

 

DANGER! 
Inadequate qualification of personnel 

Dangers  due  to  inadequate  qualification  of 

personnel! 

Possible consequence: Death or severe injury, 

significant damage to material assets. 

 

The  system  owner  must  ensure  compliance 

with the required qualifications. 

 

All  activities  must  only  be  carried  out  by 
personnel  who  are  qualified  to  perform  such 

activities. 

 

Access  to  the  system  must  be  prevented  for 
inadequately qualified personnel.. 

 

IMPORTANT NOTE! 

Compliance  with  the  applicable  accident 

prevention  regulations  and  the  other  statutory 

regulations  and  the  generally  acknowledged 
safety regulations must be ensured by the system 
owner! 
 

 

IMPORTANT NOTE! 

Only  liquid  flocculants  from  the  company 

BAYROL may be dosed with the Flockmatic. The 
use  of  flocculants  or  other  products  from  other 

manufacturers  results  in  loss  of  all  damage 
compensation claims! 
 

 

 

DANGER! 

Compliance with the protection rating 

After tasks on the Flockmatic, if the housing or 
individual cable glands are not properly closed, so 

that a reliable seal is ensured, moisture can 
penetrate into the device. 

Possible consequences: Damage or 

destruction of the Flockmatic, malfunctions. 

 

After  all  tasks  performed  on  the  device, 
ensure a safe seal.

 

 

2.

 

General 

The Flockmatic is a high quality peristaltic pump for dosing of 
flocculant (Quickflock Automatic Plus) in to the circulation 
system of a swimming pool.  

The pool must be equipped with a properly sized sand/glass 
filter.

 

 

Technical data: 

The Flockmatic is a high quality stepper motor that requires no 

gears. 
With the supplied hose, the capacity is - 0.01 l / (10ml / h). 

 

Max. pressure: 

 

 

1.5 bar 

Flow rate: 

 

 

0,01 l/h (10ml/h) 

Protection class housing: 

 

IP65 

Dimension  
(without wall mounting panel,mm): 

approx. 93x150x130 

(BxHxT) 
Electric power supply: 

 

230 V / 50 Hz 

3.

 

Electrical connection 

The Flockmatic pump must be connected in a way that it only 
works when the circulation pump is running.  

The Flockmatic must be isolated when carrying out a backwash

 

of the sand/glass filter. T

he Flockmatic must be installed in 

such a way to ensure that it is switched off during Backwashing 
of the filter.

 

The Flockmatic can easily be connected to the PoolManager

®

Please refer to the operating instructions of the PoolManager

®

4.

 

Installation in the circulation 
system 

 

The Flockmatic is supplied ready for installation on a panel for 

wall mounting. The pump is preferably mounted at a height of 
about 1.5 m on the wall. The container with  
Quickflock Automatic Plus is placed directly under the 

Flockmatic pump in order to keep the Suction tube as short as 
possible. Read the safety instructions on the label of the 

container of Quickflock Automatic Plus. Do not dispense any 
liquids other than liquid flocculant with this pump! 

 

 