Mounting / Commissioning: 

Install the injection valve using a saddle clamp if necessary

 in 

the pipe section between 

the circulation pump and the filter 

inlet.

 (See diagram).

 

 
Caution: 

Place the point of injection as far as possible away from the 
sand filter (

as close as possible to the circulation pump outlet

in order to allow the flocculating agent to build up the flakes. 
If a measurement, control and metering system is installed 
make sure to inject the liquid flocculant after the sample water 

extraction point. 
 
Connect the pressure side of the pump (right hand) with the 

injection valve by using the provided hose 6 x 4 mm. Connect 
the hose to the supplied suction lance on the suction side of the 

Flockmatic (left hand). 
Make sure all hose connections are fitting tightly! 

 

Installation diagram: 

 

 

1 - Flockmatic 
2 - Quickflock Automatic Plus 

3 - Heat exchanger 
4 - Filter 
5 - Injection after the circulation pump 

6 - Circulation pump 
7 - Injection before circulation pump (recommended if counter 
pressure is higher than 0.8 bar) 

 

PLEASE NOTE:

 Sample water extraction must be before 

injection of liquid flocking agent! 

5.

 

 Maintenance 

Some parts of the Flockmatic are subject to wear due to 
chemical and mechanical stress. Thus regular inspection is 

required for safe, long-term operation. Regular preventive 
maintenance of the system protects against unscheduled 
interruptions of operation. 

5.1

 

14-day maintentance 

 

Visual inspection of all dosing lines and the dosing hose 
for leaks, replace if necessary 

5.2

 

Yearly  maintenance 

 

inspection of all dosing lines, replace if necessary 

 

Replacement of the hose of the dosing pump 

5.3

 

Cleaning 

Clean the surfaces of the device with a soft lint-free cloth as 
needed. To do this only use a little water, if necessary 
 

 

IMPORTANT NOTE 

Do not use aggressive cleaners 

 

5.4

 

Hose replacement 

 

 

NOTE 

Never grease the hose! 

 

NOTE 

Only use original spare pump hoses! 

 

DANGER! 
Danger due to chemicals 

When pulling off the pump hose, corrosive 
product residues can escape. 

Possible consequence: Serious health 

impairment (acid burns) and damage to 
material assets 

 

Always empty the pump hose and supply 
lines first. 

 

If necessary wear protective goggles and 
protective gloves and protect the 
surroundings against escaping product 

residues with a cloth.

 

 

DANGER! 
Danger due to rotating parts  

The rotor of the dosing pump can start-up 
abruptly. 

Possible consequence: Danger of crushing 
for fingers! 

Ensure that the dosing pump remains 

disconnected from the operating voltage while 
replacing the hose (unplug the mains plug)! 

 
The hose of the dosing pump is replaced without dismounting 
the rotor. 

 

 

Remove the emptied suction and pressure hoses from the 

hose holder. To do this open the blue clamping screws. 

 

Take the transparent cover 1 off of the pump. 

 

Take off the blue cover 2 of the rotor. 

 

Turn rotor 3 in such a manner that the flat side points to 

the left and is vertical. 

 

Pull the hose holder 4 out of its holder and lift it on the left 
side. 