11
Example: if the required application rate
is 10 ounces (296ml) of treatment per
hundredweight (cwt) of seed (60lbs in 1 minute),
the desired amount of treatment that needs to
fill the calibration beaker in 1 minute would be
177.6ml...
296ml ÷ 100cwt = 2.96ml x 60lbs = 177.6
Step 6:
Note the amount of chemical pumped in one minute and compare that number to the desired application rate.
Step 7:
Empty the Graduated Beaker back into the Supply Tank.
• Adjust the LS Pump Control Speed Indicator Dial to increase or decrease Pump dispersion rate / output speed.
• Faster = more chemical pumped, slower = less.
• Repeat Steps 4-6 until the desired amount of chemical pumps in one minute.
• Once the calibration process is complete and the desired application rate is achieved, lock the Pump Speed Dial.
Continued
Note: The IP pump is rated in millilitres per
revolution. Capacity of the pump and element
will vary with the viscosity of treatment product
used. The Pump (with #82 element) has a
maximum output of 2-1/2 gallons per minute.