Single Electric 2-Phase Breast Pump

EN

5

Description

Description of accessories

 

A

PLQ

1

qf

qg

qh

qj

qk

ql

w;

2
3
4

5

6

+

7

8

9
0

qa

qs

qd

1

  Dust cap for the silicon breast pad

2

  Silicon breast pad

3

  Plastic breast brace

4

  Bottle connector 

5

  Protective nipple cap 

6

 Valve

7

 Flap

8

  Bottle opening cap

9

  Bottle adaptor  

enables the bottle opening cap 

A

8

 with nipple 

A

qa

 to be screwed on to a narrow-neck baby 

bottle .

0

  Bottle seal cap

qa

  Silicon nipple

qs

  Wide-neck baby bottle (volume 120 ml)

qd

  Bottle stand 

qf

  Bladder cap 

qg

  Inner cap stopper

qh

  Silicon bladder

qj

  Pump unit

qk

  Silicon tubing

ql

  Silicon tubing connector  

is located on both ends of the tubing 

A

qk

 .

w;

  AC adaptor

 

Replacement accessories contained in the original packaging of the breast pump: 

1 pc silicon tubing 

A

qk

 + 2 pcs silicon tubing connectors 

A

ql

, 2 pcs flap 

A

7

 .

Parts 

A

1

ql

 are made from a material that does not contain BPA (Bisphenol A). On the pump unit

 

A

qj

 

this relates to the cover and control panel.

+

+

Summary of Contents for BBP 1010

Page 1: ...ower source 8 Using the breast pump 8 Tips and advice for using the breast pump 9 Storing and heating up breast milk 9 Troubleshooting 10 Cleaning and sterilization 11 Storage 12 Technical specificati...

Page 2: ...the second phase where a deeper slower suction action of the infant is emulated In this phase breast milk is expressed from the breast nipple and pumped into a bottle The stimulation and expression in...

Page 3: ...aptor and accessories Before connecting the power adaptor to a power socket make sure the voltage stated on its rating label corresponds to the voltage in the power socket For hygiene reasons the brea...

Page 4: ...rge the pump unit or power adaptor in water or any other liquids or sterilize these parts because they do not come into contact with the breast milk or the breast Cleaning may be performed by children...

Page 5: ...o a narrow neck baby bottle 0 Bottle seal cap qa Silicon nipple qs Wide neck baby bottle volume 120 ml qd Bottle stand qf Bladder cap qg Inner cap stopper qh Silicon bladder qj Pump unit qk Silicon tu...

Page 6: ...display shows EXPRESSION 5 SUCTION scale shows the suction intensity setting 6 Power adaptor socket 7 SPEED scale shows the speed of stimulation expression 8 Increase suction intensity button 9 Decrea...

Page 7: ...y upwards so that the lip located on the nozzle slides in first Then carefully push the plastic brace A3 on to the bottle connector A4 so that these parts are connected Into the top part of the bottle...

Page 8: ...er level B2 The approximate operating time of the breast pump when new batteries are used is 60 minutes After approximately 60 minutes of operation suction intensity will decline even when the battery...

Page 9: ...fault settings will be renewed as when the breast pump was started for the first time 6 Take the breast out of the silicon pad A2 always only after turning off the pump unit Aqj Place the bottle Aqs w...

Page 10: ...to the respective bottle When necessary you can use a different baby bottle with a nipple Before feeding always first shake the bottle and check the temperature of the milk Dispose of any unused milk...

Page 11: ...r cap Aqf and the tubing Aqk with the connected tubing connectors Aql using a lightly dampened cloth Then dry both parts using a clean wiping cloth These parts do not come into contact with breast mil...

Page 12: ...ensity Max 0 016 MPa stimulation mode Max 0 034 MPa expression mode Stimulation expression speed 100 cycles minute stimulation mode 26 to 60 cycles minute expression mode Automatic shut off timer 30 m...

Page 13: ...more details In accordance with national regulations penalties may be imposed for the incorrect disposal of this type of waste For business entities in European Union states If you want to dispose of...

Reviews: