Introduction

 

It is generally accepted that breast milk is the natural diet for an infant providing the necessary nutrients 
for growth and protection against infections . A  breast milk pump is a  suitable additional accessory for 
breastfeeding mothers . It is particularly useful in situations where the mother is not able to breastfeed at 
regular intervals or when it is not possible to breastfeed directly from the breast, e .g . due to painful or fissured 
breast nipples and last but not least it helps alleviate engorgement, a painful condition where breasts are 
overfill and expression of a certain amount of milk is necessary .  

 

The BBP 1010 Bayby breast pump is equipped with a two-phase system that simulates an infant's natural 
sucking action . In the first stage, the fast suction cycle is emulated, by which the breast nipple is stimulated 
to induce the lactation of breast milk from the mammary gland . This is followed by the second phase where 
a deeper slower suction action of the infant is emulated . In this phase, breast milk is expressed from the 
breast nipple and pumped into a bottle . The stimulation and expression intensity level can be adjusted as 
necessary in 9 levels .

 

A clearly arranged LCD display shows the set operating mode, suction intensity, pumping speed and time 
remaining until automatic shut off . The memory function automatically stores the most recent operating 
mode and suction intensity settings .

 

The 3-in-1 silicon breast pad combines three functions: breast massage, breast pressing and breast milk 
expression . All these actions take place simultaneously to induce the feeling of natural breastfeeding .  The 
specially designed shape of the silicon breast pad separates milk from air and prevents milk from flowing 
in reverse .

 

The basic accessories for the breast pump include a wide-neck baby bottle and a bottle adaptor enabling 
the use of narrow-neck baby bottles . 

 

Thanks to its compact dimensions, you can always have the breast pump on hand . Because of its quiet 
operation and battery or power adaptor powered operation, it can be used both at home and when travelling .

Summary of Contents for BBP 1010

Page 1: ...ower source 8 Using the breast pump 8 Tips and advice for using the breast pump 9 Storing and heating up breast milk 9 Troubleshooting 10 Cleaning and sterilization 11 Storage 12 Technical specificati...

Page 2: ...the second phase where a deeper slower suction action of the infant is emulated In this phase breast milk is expressed from the breast nipple and pumped into a bottle The stimulation and expression in...

Page 3: ...aptor and accessories Before connecting the power adaptor to a power socket make sure the voltage stated on its rating label corresponds to the voltage in the power socket For hygiene reasons the brea...

Page 4: ...rge the pump unit or power adaptor in water or any other liquids or sterilize these parts because they do not come into contact with the breast milk or the breast Cleaning may be performed by children...

Page 5: ...o a narrow neck baby bottle 0 Bottle seal cap qa Silicon nipple qs Wide neck baby bottle volume 120 ml qd Bottle stand qf Bladder cap qg Inner cap stopper qh Silicon bladder qj Pump unit qk Silicon tu...

Page 6: ...display shows EXPRESSION 5 SUCTION scale shows the suction intensity setting 6 Power adaptor socket 7 SPEED scale shows the speed of stimulation expression 8 Increase suction intensity button 9 Decrea...

Page 7: ...y upwards so that the lip located on the nozzle slides in first Then carefully push the plastic brace A3 on to the bottle connector A4 so that these parts are connected Into the top part of the bottle...

Page 8: ...er level B2 The approximate operating time of the breast pump when new batteries are used is 60 minutes After approximately 60 minutes of operation suction intensity will decline even when the battery...

Page 9: ...fault settings will be renewed as when the breast pump was started for the first time 6 Take the breast out of the silicon pad A2 always only after turning off the pump unit Aqj Place the bottle Aqs w...

Page 10: ...to the respective bottle When necessary you can use a different baby bottle with a nipple Before feeding always first shake the bottle and check the temperature of the milk Dispose of any unused milk...

Page 11: ...r cap Aqf and the tubing Aqk with the connected tubing connectors Aql using a lightly dampened cloth Then dry both parts using a clean wiping cloth These parts do not come into contact with breast mil...

Page 12: ...ensity Max 0 016 MPa stimulation mode Max 0 034 MPa expression mode Stimulation expression speed 100 cycles minute stimulation mode 26 to 60 cycles minute expression mode Automatic shut off timer 30 m...

Page 13: ...more details In accordance with national regulations penalties may be imposed for the incorrect disposal of this type of waste For business entities in European Union states If you want to dispose of...