Model
RAD
Top loading scale
User’s Guide
25
ES
FR
ENG
9. PARAMETERS
The scale has 12 parameters that can be set by the user. These allow the user to set the scale to:
▪ Display the weight in other increments of weight to minimize the affects of vibration, wind or other environmental conditions.
▪ Control the back light on the display. It may be necessary to turn the backlight off to maximize battery life.
▪ Set the RS-232 work mode.
▪ Set whether accumulation when print.
▪ Set auto zero range.
▪ Select another weighing unit than the standard.
▪ Set beeper on condition (check weighing).
▪ Set ADC speed.
To set parameters press the
and
keys at the same time.
The display will show “Incxx”. The first value shown is the default scale increment value. To select a different increment value press the
key to change the value then press the
key.
For example on a 15kg scale the standard increment is 0.5g, the value can be changed to 1,0g or 2,0g.
The next parameter is control of the backlight. The standard is to have the backlight operate automatically, turning off when the scale
is not used. The backlight can be set to be “BKOn”, “BKAu” (Automatic) or “BKOff”. The maximum battery life is achieved with the
backlight turned off.
Press the
key to change the value then press the
key.
RS-232 mode is next. With “AuOn” the memory will accumulate the weight automatically (auto print mode), “AuOff” will enable the
manual accumulation (manual print mode) and with “P Cont” set the RS-232 interface will send the weight continuously (computer
mode). “ASK” is ask mode (bi direction mode), scale will operated by RS-232 command.
T
Tare operate
Z
Zero operate
R
Send current weighing data to PC
Press the
key to change the value then press the
key.
Then display show “b xxx”, this is baud rate, you can use
key to select 600bps/1200bps/4800bps/9600bps, press
to sure.
If you set as “AU on” or “AU off” (print mode), then display shows “TP”/ “LP-50” / “EPM” or / “OFF”, this printer type, EPM205 is the
internal thermal label printer, you can use
key to select, or set it as “OFF”. Use
key to sure.
If you set as “LP-50”, then display will show “ENG” or “CHI”, this is print format, “ENG” is English, “CHI” is Chinese, you can use
key to select, press
key to sure.
Whether accumulation when print is next, With “ACC ON” when you print it will accumulation, “ACC OF” will only print without accu-
mulation.
Press the
key to change the setting then press the
key.
Auto zero range tracking is next, you can select 0.5d, 1d, 2d and 4d.
Press the
key to change the setting then press the
key.
The displayed unit of weight is set next. The scales are normally calibrated and display in kilograms, however they will show the weight
in grams, ounces or pounds and selected by this function.
Press the
key to change the value then press the
.
When the scales are set to display in other units of weight the accumulation function is still keeping the weight in kilograms.