INSTRUCTIONS
Solo Innova
Page 11
1.4.2
Fan
The total air flow is set at the factory.
1.4.3
Thermal outflow protection
The standard version of the Solo Innova does not have a cooling spiral. This spiral can
be mounted to the left or the right.
1.4.4
Flue gas turbulators
The flue gas turbulators are in the heat exchanger pipe and reduce the flue gas
temperature.
1.4.5
Load valve
The thermostatic load valve enables the boiler to remain at a high temperature. As the
valve only opens at 65°C, the boiler thermostat must be set higher (i.e. fixed max. 90-
95°C). The load valve is supplied as a separate valve or as a complete pipe complex
ready for installation in the boiler. (See functional description of the load valve in
Section 4.3).
The guarantee is not valid unless a thermostatic load valve is installed.
1.4.6
Draught limiter
If the chimney draught is excessive, a draught limiter can be built into the chimney (see
Section 3.3.3).