10
FLOOR&CEILING UNITS
Kits
RZC50
RZC70
RZC100
RZC120
RZC140
RZC160
Type
ULTRA DC
Inverter
ULTRA DC
Inverter
ULTRA DC
Inverter
ULTRA DC
Inverter
ULTRA DC
Inverter
ULTRA DC
Inverter
Cooling capacity nom.(min.-
max.) (kW)
5,00(1,53-
5,60)
7,00(2,16-
8,20)
10,5(2,9-
12,0)
12,1(3,2-
13,2)
14,00(4,10-
16,00)
16,00(4,80-
17,30)
Heating capacity nom.(min.-
max.) (kW)
5,60(1,40-
6,20)
8,00(1,98-
9,30)
12,5(2,6-
13,2)
13,5(3,0-
14,7)
16,00(4,60-
17,50)
17,00(4,90-
18,50)
SEER/SCOP
6,1/4,0
6,1/4,0
6,1/4,0
5,6/4,0
5,6/4,0
5,6/4,0
Energy rating
cooling/heating
A++/A+
A++/A+
A++/A+
A+/A+
A+/A+
A+/A+
Power consumption cooling
nom.(min.-max.) (kW)
1,54(0,47-
2,30)
2,05(0,67-
3,56)
3,37(0,71-
4,71)
4,28(0,8-
5,39)
4,95(1,21-
6,48)
5,80(1,38-
6,85)
Current consumption
cooling nom.(min.-max.) (A)
6,76(2,25-
10,10)
9,02(3,21-
15,63)
14,93(3,84-
20,67)
18,97(4,35-
23,66)
7,76(2,50-
10,39)
9,10(2,85-
10,99)
Power consumption heating
nom.(min.-max.) (kW)
1,55(0,46-
2,25)
2,20(0,65-
3,62)
3,68(0,47-
4,13)
4,10(0,58-
4,90)
4,57(0,92-
5,66)
4,96(0,98-
6,00)
Current consumption
heating nom.(min.-max.) (A)
6,81(2,20-
9,88)
9,65(3,11-
15,90)
16,31(2,57-
18,3)
18,19(3,14-
21,74)
7,17(1,90-
9,08)
7,78(2,02-
9,62)
Max. power consumption
(kW)
2,40
3,80
5,37
5,68
7,00
7,50
Max. current consumption
(A)
13,04
20,65
23,6
24,9
10,31
11,05
Power supply
(V~,Hz,Phases)
220~240,
50,1
220~240,
50,1
220~240,
50,1
220~240,
50,1
380~415,
50,3
380~415,
50,3
Liquid piping diameter
(inch/mm)
1/4"/6.35
3/8"/9.52
3/8"/9.52
3/8"/9.52
3/8"/9.52
3/8"/9.52
Gas piping diameter
(inch/mm)
1/2"/12.7
5/8"/15.88
5/8"/15.88
5/8"/15.88
3/4"/19,05
3/4"/19,05
Indoor unit
RZNC50
RZNC70
RZNC100
RZNC120
RZNC140
RZNC160
Power supply wires (mm
2
)
2x1,0+E
2x1,0+E
2x1,0+E
2x1,0+E
4x1,0+E
4x1,0+E
Connection wires (mm
2
)
2x0,2
2x0,2
2x0,2
2x0,2
2x0,2
2x0,2
Dimensions
width/height/depth (mm)
930×660×2
05
1280×660×
205
1630×660×
205
1630×660×
205
1630×660×
205
1630×660×
205
Weight (kg)
25
32
44
44
44
44
Air flow volume Hi/Me/Lo
(m3/h)
900/730/65
0
1300/1052/
920
1800/1550/
1350
1800/1550/
1350
2000/1600/
1400
2000/1600/
1400
Sound pressure Hi/Me/Lo
dB(A)
45/42/37
47/45/43
53/50/47
53/50/47
54/50/46
54/50/46
Sound power dB(A)
55
57
63
63
64
64
Outdoor unit
RZT50
RZT70
RZT100
RZT120
RZT140
RZT160
Power supply wires (mm
2
)
2x2,5+E
2x4,0+E
2x6,0+E
2x6,0+E
4x1,5+E
4x1,5+E
Dimensions
width/depth/height (mm)
800×286×
530
890×320×
670
940×368×
1366
940×368×
1366
940×368×
1366
940×368×
1366
Weight (kg)
40
53
93
93
108
108
Sound pressure dB(A)
55
58
58
58
59
59
Sound power dB(A)
64
66
67
67
68
68
Refrigerant type (GWP)*
R410A (2088)
Refrigerant quantity (kg)
1,28
1,90
2,85
2,85
3,70
3,70
tCO2 eq.
2,67
3,97
5,95
5,95
7,73
7,73
Meters of precharge gas
quantity (m)
8
8
8
8
8
8
Additional charge (g/m)
20
50
50
50
50
50
Max. discharge pressure
(MPa)
4,15
4,15
4,15
4,15
4,15
4,15
Max. suction pressure
(MPa)
1,15
1,15
1,15
1,15
1,15
1,15
*These Air Conditioners contain fluorinated greenhouse gases covered by Kyoto protocol.
Summary of Contents for RZNC100
Page 6: ...6 CURVAS DE CAUDAL PRESIÓN DISPONIBLE UNIDADES CONDUCTO ...
Page 80: ...16 Localização dos ganchos de suspensão Modelo 50 Modelo 70 Modelo 100 120 140 160 ...
Page 129: ...7 Fan characteristics ...
Page 130: ...8 N B Turbo speed can be only selected with remote control Not available for wired control ...