INSTRUCTIONS FOR FITTERS
71.05086.02 - EN
This is a high static head pump fit for installation on any type of single or double-pipe heating system. The air vent valve
incorporated in the pump allows quick venting of the heating system.
25. PUMP CAPACITY/ HEAD
WATER FLOW RATE (l/h)
020516_0500
PUMP HEAD
(mH
2
O)
Drain the water in the storage boiler as follows:
• close the water inlet tap;
• open a user tap;
• unscrew the ring nut from the relative drain tap (fig. 14);
• loosen the nut on the DHW outlet pipe on the storage boiler.
26. DRAINING THE STORAGE BOILER
27. CONNECTING THE EXTERNAL PROBE
The boiler is prearranged for connection of an external probe (supplied as accessory).
For the connection, refer to the figure below (terminals 3-4) and the instructions supplied with the probe.
When the external probe is connected it is possible to adjust the heating delivery temperature in two different ways.
If the climate controller is installed in the boiler (section 18.1), the adjustment of the heating delivery temperature depends
on the
K REG
curve (graph 3), manually set using the b/-
.
If the climate controller is installed on the wall (section 18.2), the adjustment of the heating delivery temperature is auto-
matic. The electronic management automatically sets the correct climate curve, depending on the external temperature
and on the ambient temperature found (see also section 20.1).
IMPORTANT:
the value of the delivery temperature
TM
depends on the F16 parameter setting (section 21). The ma-
ximum settable temperature may 85° or 45 °C.
Figure 16
0801_0902 / CG_1852
TERMINAL BLOCK
M2
CN5