CALLING IN THE AUTHORISED TECHNICAL SERVICE CENTRE
If the symbol
appears on the display together with the symbol
, contact the
AUTHORISED TECHNICAL SERVICE CENTRE
.
Before calling, note down the fault code/s and the short message accompanying the fault.
If a fault code is displayed that is not included in the list or if a certain fault occurs frequently, contact the AUTHORISED
TECHNICAL SERVICE CENTRE.
FAULTS TABLE
Description of fault
Description of fault
10
External probe sensor
125
No circulation safety trip
(control performed via a temperature sensor)
20
NTC flow sensor
128
No flame
28
NTC fumes sensor
130
Fumes NTC tripped due to overtemperature
40
NTC flow sensor
133
Ignition failure (4 attempts)
50
NTC DHW sensor
(only for heating-only model with storage boiler)
151
Boiler board internal fault
52
Solar DHW sensor (if connected to a solar plant)
152
Generic parameter setting error
73
Solar manifold sensor (if connected to a solar plant)
160
Fan fault
83
Communication problem between boiler board and
control unit. Probable short circuit on wiring.
321
NTC domestic hot water sensor faulty
84
Address conflict between control units
(internal fault)
343
Generic parameter setting error of solar plant
(if connected to a solar plant)
109
Air in boiler circuit (temporary fault)
384
Abnormal light (parasite flame – internal fault)
110
Safety thermostat tripped due to overtemperature.
(pump blocked or air in heating circuit)
385
Input voltage too low
111
Safety thermostat tripped due to overtemperature.
386
Fan speed threshold not reached
117
Pressure in hydraulic circuit too high
430
No circulation safety trip
(control performed via a pressure sensor)
118
Pressure in hydraulic circuit too low
8. FILLING THE SYSTEM
Regularly check that the pressure displayed on the pressure gauge
B
is 1 - 1.5 bar, with
the boiler cold. If the pressure is too low, turn tap “
A
” to fill the boiler (figure to side). Open
the tap very slowly in order to vent the air.
A
Boiler/system filling tap
B
Pressure gauge
Take special care when filling the heating system. In particular, open any thermostat
valves in the system, ensure the water enters slowly in order to prevent the formation
of air inside the primary circuit until operating pressure is reached. Lastly, vent any
radiators in the system. BAXI declines all liability for damage deriving from the presence of
air bubbles in the primary exchanger due to the incorrect or imprecise observance of the
above.
The boiler is fitted with a hydraulic pressure gauge which prevents the boiler from
working if there is no water.
If pressure drops occur frequently, have the boiler checked by the AUTHORISED
TECHNICAL SERVICE CENTRE.
Summary of Contents for LUNA PLATINUM
Page 25: ...25 7110317 02 3 10 14...
Page 49: ...49 7110317 02 3 10 14...
Page 73: ...73 7110317 02 3 10 14...
Page 99: ...99 7110317 02 3 10 14...
Page 125: ...125 7110317 02 3 10 14...
Page 126: ...7110317 02 3 10 14 126 S E C T I O N A LUNA PLATINUM GA 24 33 LUNA PLATINUM GA 1 12 1 18 1 24...
Page 132: ...7110317 02 3 10 14 132 S E C T I O N C...
Page 134: ...7110317 02 3 10 14 134 S E C T I O N C 25 mm S E C T I O N D...
Page 136: ...7110317 02 3 10 14 136 S E C T I O N E...
Page 137: ...137 S E C T I O N F 7110317 02 3 10 14...