5. BOILER INFORMATION MENU
Press
to display the information indicated in the following table. Press
to exit.
Description
Description
00
SW Diagnostic Code
12
Ion current
01
+HDWLQJÀRZWHPSHUDWXUH
13
Burner working hours
02
2XWGRRUWHPSHUDWXUHLIWKHRXWGRRUVHQVRULV¿WWHG
14
Zone 1 heating mode
03
([WHUQDOVWRUDJHWDQNWHPSHUDWXUH¿WWHGPRGHOV
15
Zone 2 heating mode
04
'+:WHPSHUDWXUH¿WWHGPRGHOV
16
DHW circuit operating mode
05
Water pressure in heating system
17
Boiler operating mode
06
Heating return temperature
18
Solar plant operating mode
07
Flue sensor temperature
19
Manufacturer information
08
Not used
20
Manufacturer information
09
Solar collector temperature
21
Gas energy consumption in HEATING
10
=RQHKHDWLQJÀRZWHPSHUDWXUH
22
Gas energy consumption in DHW
11
=RQHKHDWLQJÀRZWHPSHUDWXUH
23
Gas energy consumption in H DHW
Items 21, 22 and 23 are displayed alternatively with the gas energy consumption value expressed in millions, thousands and units
of kWh. e.g.: 21 / 033 / 145 / 827 corresponds to a gas energy consumption in HEATING of 33.145.827 kWh.
6. FILLING THE SYSTEM
Periodically check that the pressure displayed on the pressure gauge is
1 - 1.5
bar, when the system water temperature is cold. If
WKHSUHVVXUHLVORZHUWXUQWKHV\VWHP¿OOLQJWDSLQVWDOOHGE\WKHLQVWDOOHU2SHQWKHWDSYHU\VORZO\LQRUGHUWRYHQWWKHDLU
7KHERLOHULV¿WWHGZLWKDK\GUDXOLFSUHVVXUHJDXJHZKLFKSUHYHQWVWKHERLOHUIURPZRUNLQJLIWKHUHLVQRZDWHU
,ISUHVVXUHGURSVRFFXUIUHTXHQWO\KDYHWKHERLOHUFKHFNHGE\WKH$87+25,6('7(&+1,&$/6(59,&(&(175(
7. ROUTINE MAINTENANCE INSTRUCTIONS
7RNHHSWKHERLOHUHI¿FLHQWDQGVDIHKDYHLWFKHFNHGE\WKH$XWKRULVHG6HUYLFH&HQWUHDWWKHHQGRIHYHU\RSHUDWLQJSHULRG
Careful servicing ensures economical operation of the system.
8. SWITCHING OFF THE BOILER
To turn off the boiler, disconnect the electric power supply using the two-pole switch. In the “Off” operating mode the boiler stays
off but the electrical circuits remain powered and the anti-freeze function remains active.
Summary of Contents for LUNA DUO-TEC MP+ 1.115
Page 27: ...7690785 01 1 05 18 96 S E C T I O N B 7685789...
Page 29: ...7690785 01 1 05 18 98 S E C T I O N C...
Page 31: ...7690785 01 1 05 18 100 S E C T I O N D 25 mm...
Page 34: ...103 S E C T I O N F 7690785 01 1 05 18 AGU 2 550 CR_0349 CR_0349 AVS 75 bis...
Page 35: ...7690785 01 1 05 18 104 S E C T I O N F CG_2482 Tmax 50 C...
Page 37: ...7690785 01 1 05 18 106...
Page 38: ...107 7690785 01 1 05 18...
Page 39: ...7690785 01 1 05 18 DVVDQR GHO UDSSD 9 7 9LD 7UR HWWL 6HUYL LR FOLHQWL WHO 7HOHID ZZZ ED L LW...