background image

7219707 - 01 (04/15)

0086

Baxi Customer Support

0344 871 1525

Opening hours

Monday - Friday, 8.00am-6.00pm
Weekends and Bank Holidays, 8.30am-2.00pm

Please note calls may be recorded for training and monitoring purposes

baxi.co.uk

Register now to activate your warranty:

www.baxi.co.uk/registration

For the warranty to be maintained, please make sure...

Benchmark checklist is completed
Warranty is registered with Baxi
The boiler has an annual service

1

2

3

For full terms and conditions, visit www.baxi.co.uk/terms. Failure to adhere to
terms and conditions will void your manufacturer’s warranty.

Baxi
Brooks House,
Coventry Road,
Warwick, CV34 4LL

Please ensure the boiler is installed in accordance with these installation
instructions and that you adhere to the Building Regulations.

e&oe
All descriptions and illustrations provided in this document have been
carefully prepared but we reserve the right to make changes and
improvements in our products which may affect the accuracy of the
information contained in this leaflet. All goods are sold subject to our
standard Conditions of Sale which are available on request.

Summary of Contents for Ecoblue plus combi 24

Page 1: ...lus Combi User Guide Gas Fired Wall Mounted Condensing Combination Boiler 24 28 33 en United Kingdom Please keep these instructions in a safe place If you move house please hand them over to the next...

Page 2: ...Baxi EcoBlue Plus 24 Combi ErP G C No 47 077 08 Baxi EcoBlue Plus 28 Combi ErP G C No 47 077 09 Baxi EcoBlue Plus 33 Combi ErP G C No 47 077 10 0086 Baxi Heating UK Ltd 2015 All rights reserved No par...

Page 3: ...cription 4 2 Operating Principle 4 2 1 In Operation 4 3 Control Panel Description 4 4 Standard Delivery 4 5 Accessories Options 4 5 1 Optional Extras 5 Operation 5 1 Operation Checking Procedure Basic...

Page 4: ...Environmental 11 1 Energy Saving 11 2 Room Thermostats and Settings 12 Warranty 12 1 General 12 2 Terms of Warranty 12 2 1 Standard Warranty Terms and Conditions 13 Appendix 13 1 ErP Information 13 1...

Page 5: ...ly at the owner s risk If the appliance is used for purposes other than or in excess of these specifications the manufacturer will not accept any liability for resulting loss damage or injury The manu...

Page 6: ...or faulty or inadequate maintenance of the appliance Failure to abide by the instructions on installing the appliance This company declares that no substances harmful to health are contained in the a...

Page 7: ...n how to operate the appliance correctly Do not allow children to operate or play with the appliance 1 5 2 Installer s Responsibility The installer is responsible for the installation and initial star...

Page 8: ...the gas supply at the meter 2 Open windows and doors in the hazardous area 3 Do not operate light switches 4 Do not operate any electrical equipment 5 Do not use a telephone in the hazardous area 6 Ex...

Page 9: ...t and that you have signed it to say that you have received a full and clear explanation of its operation The installer is legally required to complete a commissioning checklist as a means of complyin...

Page 10: ...pply External Fuse Rating 3A NOTE All data in this section are nominal values and subject to normal production tolerances IMPORTANT Where Low Flow Taps or Fittings are intended to be used in the DHW s...

Page 11: ...4 Priority is given to domestic hot water 5 The boiler model serial number and Gas Council number are also shown on the information label behind the boiler control flap Fig 1 This is for user referen...

Page 12: ...demand Heating mode symbol will flash with demand Units for temperature Units for pressure Service due Display Description Central Heating CH Temperature Adjustment Boiler Information View Standby Res...

Page 13: ...24 hr Plug in Digital Timer 7 day Plug in Single Channel Timer Wired Two Channel Timer Wired RF Digital Programmable Room Unit Wireless RF Mechanical Programmable Room Unit Wireless Condensate Dischar...

Page 14: ...for heat Is the Room Thermostat if fitted set high enough 12 1 2 3 4 5 6 7 8 9 1 0 11 Typical examples of external timer Ensure timer is set for Central Heating ON see any instructions supplied with t...

Page 15: ...Is the Spanner symbol illuminated or flashing YES Spanner Symbol Error Code Flame Failure OR If you don t know what you need to do to get the boiler to light or need help with the system and controls...

Page 16: ...o be turned off Your installer will be able to offer advice 1 The boiler incorporates an integral frost protection feature that will operate in both Central Heating and Domestic Hot Water modes and al...

Page 17: ...Heating Only mode Domestic Hot Water will NOT be supplied when a hot tap is opened See 6 1 1 or 6 1 2 to set the required temperature Summer Domestic Hot Water only mode Winter Domestic Hot Water Cen...

Page 18: ...h a damp cloth and then dried completely DO NOT USE ABRASIVE CLEANING AGENTS 1 The central heating system should be checked regularly Proceed as follows Check the water pressure in the central heating...

Page 19: ...onnected between the two taps Ensure that the nuts on the pipe ends are tightened onto the taps 7 Fully open one of the taps first and then while watching the pressure gauge carefully open the second...

Page 20: ...itch off the boiler 5 Vent the radiators Work from the lowest radiator in the property 6 Open the bleed vent with the key keeping a cloth pressed against the vent 7 Wait until water comes out of the b...

Page 21: ...rs are cold 4 Connect a drain hose to the lowest draining point Place the end of the hose in a drain or at a place where drained water will not cause any damage 5 Open the CH system drain valve Drain...

Page 22: ...ton and holding for two seconds Error Code 118 can be reset by restoring the correct system pressure as described in Section 7 3 R P R R Table Of Error Codes WARNING If an error code different from th...

Page 23: ...e the system Flow must be at least 2 5 litres per minute Increase the value with the CH temperature button or if a room thermostat is connected increase the temperature on the room thermostat Activate...

Page 24: ...ed Switch off the boiler Switch off the boiler s electrical connection Close the boiler gas valve Drain the CH system Seek the advice of your installer CAUTION Only qualified professionals are authori...

Page 25: ...er pointlessly Fit a water saving shower head to save up to 40 energy Take showers rather than baths A bath consumes twice as much water and energy 11 2 Room Thermostats and Settings Various models of...

Page 26: ...ms Benchmark Checklist The Benchmark Checklist will be completed by your installer and records that the boiler has been installed and commissioned correctly It can be found at the back of the installa...

Page 27: ...rrange for one of our nationwide team of Gas Safe registered engineers to visit If your product is in warranty everything is free of charge subject to our warranty terms and conditions If it is out of...

Page 28: ...A A A Water heating energy efficiency class A A A Rated heat output Prated or Psup kW 20 24 28 Space heating Annual energy consumption kWh GJ 17204 62 20645 74 24086 87 Water heating Annual energy con...

Page 29: ...B e g a k c a p f o s s a l c y c n e i c fi f e y g r e n e g n i t a e h e c a p s l a n o s a e S e g a k c a p f o y c n e i c fi f e y g r e n e g n i t a e h e c a p s l a n o s a e S R O n i y...

Page 30: ...ematical expression 115 11 Prated whereby Prated is related to the preferential space heater Weighting of boilers 0 0 0 0 1 0 3 0 37 0 2 0 55 0 70 0 3 0 75 0 85 0 4 0 85 0 94 0 5 0 95 0 98 0 6 0 98 1...

Page 31: ...i l c e g a r e v a r e d n u e g a k c a p f o y c n e i c fi f e y g r e n e g n i t a e h r e t a W y t i c i r t c e l e y r a i l i x u A n o i t u b i r t n o c r a l o S r e t a e h n o i t a...

Page 32: ...l terms and conditions visit www baxi co uk terms Failure to adhere to terms and conditions will void your manufacturer s warranty Baxi Brooks House Coventry Road Warwick CV34 4LL Please ensure the bo...

Reviews: