3.0 Repressurising System

6

© Baxi Heating UK Ltd 2010

bar

0

1

2

3

4

bar

0

1

2

3

4

3.1

Central Heating System Pressure

1. The normal operating water pressure is between 1
and 2.5 bar (Fig. 1). If the pressure exceeds 3 bar the
safety pressure valve will operate and a fault is indicated.
Contact your installer.

2. It may be necessary to repressurise the system
occasionally (Fig. 2). A filling device (the filling loop) will
be fitted on the system. This will be on the boiler itself,
or on pipework near to the boiler.

3. If you are unsure of its position, or cannot identify it,
consult the installer who fitted the boiler.

4. The filling loop consists of two taps and a separate
copper pipe with connection fittings.

5. Only when repressurising should the copper pipe be
connected between the two taps. Ensure that the nuts
on the pipe ends are tightened onto the taps.

6. Fully open one of the taps first, and then while
watching the pressure gauge, carefully open the second
tap.

7. When the needle on the gauge is indicating 1 or more
turn both taps off.

8. Disconnect the copper pipe from the taps (a small
amount of water may be present) and remove it. Keep
the pipe in a safe place for future use.

Fig. 1

Fig. 2

Normal Pressure

Requires

Repressurising

Summary of Contents for Duo-tec Combi HE LPG

Page 1: ...g UK Ltd 2010 Duo tec Combi HE LPG Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place If you move house please hand them over to the next occupie...

Page 2: ...a copyright work may be liable to criminal prosecution and civil claims for damages 1 0 Quick Reference Guide 3 2 0 Troubleshooting 4 3 0 Repressurising System 6 4 0 Clearances 7 5 0 Care of the Boile...

Page 3: ...en the boiler is in the central heating mode Domestic Hot Water Indicator The indicator will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicator will illum...

Page 4: ...to the boiler is switched on Is the display lit Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating...

Page 5: ...imer Is the Room Thermostat if fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boile...

Page 6: ...ear to the boiler 3 If you are unsure of its position or cannot identify it consult the installer who fitted the boiler 4 The filling loop consists of two taps and a separate copper pipe with connecti...

Page 7: ...r 6 Your boiler should have the following minimum clearances for Safety and Maintenance Figs 3 4 Top 200mm Bottom 150mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing This is...

Page 8: ...is shown as E then 50 3 E20 E28 E50 E125 E160 indicate faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 or E130 is display...

Page 9: ...boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0085 Product Production certified by Notified Bodies 0086 For GB IE only 6 2 Benchmark Commi...

Page 10: ...Supplied By www heating spares co Tel 0161 620 6677 7 0 Notes 10 Baxi Heating UK Ltd 2010...

Page 11: ...lves are positioned under the boiler and can be closed by turning their taps to the right towards the wall Fig 6 3 Call your Installer or Service Engineer as soon as possible Warning IMPORTANT This bo...

Page 12: ...u should always contact your installer first because the cause of the fault may not be related to the boiler If your installer confirms that the fault is with the boiler and he she can t repair it our...

Reviews: