Baxi Duo-tec Combi HE LPG User Operating Instructions Manual Download Page 11

Supplied By www.heating spares.co  Tel. 0161 620 6677

8.0 Emergency

11

© Baxi Heating UK Ltd 2010

Gas Tap

Heating Flow, Heating

Return and Mains Water

Inlet Isolating Valves

Fig. 6

In an Emergency

If a water or gas leak occurs or is suspected, the boiler can
be isolated at the inlet valves as follows;

1. Using a suitable open ended spanner, turn the square
nut on the gas tap through 90° (

1

/

4

turn) to isolate the gas

supply at the boiler (Fig. 6).

2. The water isolating valves are positioned under the
boiler and can be closed by turning their taps to the right
towards the wall (Fig. 6).

3. Call your Installer or Service Engineer as soon as
possible.

Warning !

IMPORTANT

This boiler operates on LPG (Propane). Familiarise
yourself with any control and isolation valves. If in
doubt consult your installer about the operation of
these devices.

If you smell gas

Turn off the gas supply and call your gas supplier
immediately. It is possible to isolate the boiler at the
isolating valve (Fig. 6).

Faulty boiler

If it is known or suspected that a fault exists 
on the boiler, it must not be used until the fault 
has been corrected by a competent person.

Summary of Contents for Duo-tec Combi HE LPG

Page 1: ...g UK Ltd 2010 Duo tec Combi HE LPG Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place If you move house please hand them over to the next occupie...

Page 2: ...a copyright work may be liable to criminal prosecution and civil claims for damages 1 0 Quick Reference Guide 3 2 0 Troubleshooting 4 3 0 Repressurising System 6 4 0 Clearances 7 5 0 Care of the Boile...

Page 3: ...en the boiler is in the central heating mode Domestic Hot Water Indicator The indicator will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicator will illum...

Page 4: ...to the boiler is switched on Is the display lit Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating...

Page 5: ...imer Is the Room Thermostat if fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boile...

Page 6: ...ear to the boiler 3 If you are unsure of its position or cannot identify it consult the installer who fitted the boiler 4 The filling loop consists of two taps and a separate copper pipe with connecti...

Page 7: ...r 6 Your boiler should have the following minimum clearances for Safety and Maintenance Figs 3 4 Top 200mm Bottom 150mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing This is...

Page 8: ...is shown as E then 50 3 E20 E28 E50 E125 E160 indicate faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 or E130 is display...

Page 9: ...boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0085 Product Production certified by Notified Bodies 0086 For GB IE only 6 2 Benchmark Commi...

Page 10: ...Supplied By www heating spares co Tel 0161 620 6677 7 0 Notes 10 Baxi Heating UK Ltd 2010...

Page 11: ...lves are positioned under the boiler and can be closed by turning their taps to the right towards the wall Fig 6 3 Call your Installer or Service Engineer as soon as possible Warning IMPORTANT This bo...

Page 12: ...u should always contact your installer first because the cause of the fault may not be related to the boiler If your installer confirms that the fault is with the boiler and he she can t repair it our...

Reviews: