background image

Baxi Gas Stoves

23

BAXI SPARE PARTS LIST

1.

Baxi Burnmoor

Coal Set

AFGS088

AFGS088A

AFGS089

AFGS089

AFGS090

AFS090

AFS091A

AFS091

AFS1042

AFS1042

AFS047

AFS047

1a.

Becton Furness

Coal Set

2.

Co-pilot

Assembly

3.

Elbow Injector

4.

Gas Control

Valve

5.

Control Door

Magnet.

6.

Hinge Kit To Fit

Both Doors
Comprises 2 Hinges
& 4 Fixings Per Set.

Part Description

Visual Aid

(not to scale)

Baxi

Furness

Part No.

Baxi

Burnmoor

Part No.

Summary of Contents for BURNMOOR

Page 1: ...gton Birmingham B24 9QP FURNESS AND BURNMOOR GAS STOVES Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE FOR USE IN COUNTRIES GB IE Rev 8 Furness G C No 32 075 36 Burnmoor G C No 32 075 37 Baxi Furness ...

Page 2: ... service please call 0870 609 0081 To help us quickly help you please try to have the following information available before you contact us a Your Post Code b Type of Fire c Model Name d Serial Number e The Fault Problem or Request 2 Baxi Gas Stoves HELP LINES www baxifires co uk Baxi Fires Division Wood Lane Erdington Birmingham B24 9QP ...

Page 3: ... Hearth Requirements 14 Connecting The Gas Supply 14 Pressure Test Sequence 14 Fire Testing 15 Final Installation Check List 16 Page SERVICING Detail of Pilot Assembly 17 Door Trim and Fire Glass Fitting Removal 18 Component Replacement 19 Replacement of the Door Seal 19 Regular Service 19 Annual Service 20 Cleaning Outer Services 20 Cleaning Door Glass 20 Fault Diagnosis 21 SPARE PARTS General Co...

Page 4: ...her debris accumulated in and around the appliance This should be performed before and after the installation It is recommended that any replacement item s are not broken up but sealed within a heavy duty polythene bag and clearly labeled R C F waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothing ...

Page 5: ...he control knob the control door handle and control door are considered to be working surfaces Warning Under no circumstances must the fire be operated with the door open or if the glass is cracked or broken Warning If it is known or suspected that an operational or ignition fault exists on the appliance it must not be used until it has been corrected by a competent person Warning THIS GAS APPLIAN...

Page 6: ...e pointing towards the centre of the fire Once the reflective panels are fitted arrange the coals See Arranging the coals Category I2H For use in GB and IE at a supply pressure of 20mbar TECHNICAL DATA Baxi Furness Natural Gas Baxi Burnmoor Natural Gas Main Burner Injector Max Heat Setting Heat Input net 3 3 kW 4 2 kW Heat Ouput net Gas Rate 0 349 m3 hour 0 444 m3 hour Cold Setting Pressure 1 5mb ...

Page 7: ...plate centrally between the end tabs of the location bar Fig 3a Fig 3a Step 2 Place the rear matrix cut out section over the base matrix and centralise the assembly between the end tabs of the location bar Ensure the rear matrix is pushed back against the location bar Fig 3b Fig 3b Step 3 Locate 2 off end coals each side of the base matrix See underside of coals for hand identification Fig 3c Fig ...

Page 8: ...ition Fig 4b Fig 4b Step 1c Keep the control knob pressed in for a further 15 seconds and then release The pilot will remain alight If pilot does not remain alight repeat this procedure Please note that when purging the gas supply it is usual to have to keep the control knob depressed in the spark position for longer periods of time Step 2 To ignite the main burner rotate the control knob anti clo...

Page 9: ...unning no attempt should be made to re light the gas for at least three minutes To restart the fire turn the control knob to the off position and repeat the lighting controlling the fire instructions The flame failure device is a safety feature required by law and must not be put out of action by the installer If this device or any of its parts are to be replaced only original manufacturer s parts...

Page 10: ...iner kite marked to BS715 must be used The Furness requires a minimum flue system of 101mm diameter 4 inches The Burnmoor requires a minimum flue system of 127mm diameter 5 inches The minimum effective height of the chimney must be 3 metres it must be terminated with a suitable chimney pot or cowl and the chimney or flue shall be swept prior to installation unless the previous appliance was a gas ...

Page 11: ...ight of 600mm of flue measured from the top of the appliance See figure 6c Move the fire with flue spigot in place into position under the flue and seal the spigot flue connection with fire cement Ref fig 5c It is recommended that a smoke test is performed inside the fire to ensure that adequate flue draw is evident Fig 6a Fig 6b Fig 6c Baxi Gas Stoves 11 INSTALLATION non combustible closure plate...

Page 12: ...b For clearance from the top of the fire to any combustible shelf Fig 6a See Graph 1 There must be a minimum of 230mm from the rear of the fire to any combustible back wall Fig 6a With a Non combustible back wall the fire can be pushed back until the top diverter touches the wall although to improve access and air circulation a minimum distance of 100 mm is recommended Reference non combustible si...

Page 13: ...helf or other projection made of wood or any other combustible material is shown on graph 1 Graph 1 Combustible Shelf Clearances The recommended minimum height from the extreme top surface of the fire to the underside of a non combustible shelf is 100mm Baxi Gas Stoves 13 INSTALLATION ...

Page 14: ...cted with the 1 4 BSP nut and olive with 8mm tubing A maximum pipe run of 1 5 metres or 5 feet should be adhered to and copper tubing may be used provided a distance of 25mm is maintained between pipe work and any surface of the fire A gas service cock should be fitted adjacent to the fireplace to enable safe removal of the appliance for servicing After fitting the supply operate the gas cock supp...

Page 15: ...If this does not occur the appliance must be disconnected and the flue checked Step 5 If there is an extractor fan in any room this must be turned on and any doors between it and the fire left open repeat the spillage test Repeated operation of the spillage monitoring system indicates that there maybe a flue draw problem In this situation no more attempts at operating the appliance should take pla...

Page 16: ...appliances only c If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used d If an existnig chimney has been refurbished with a new liner type or make of liner fitted e Details of flue outlet terminal and diagram reference Outlet Details Complies with f Number and angle of bends g Provision for cleaning and recommended...

Page 17: ... permanently This will keep the fire and its components including the ceramic coal set in a warmer state and give instant ignition to the burner This in turn will reduce condensation in the chimney and any flue problems associated with this Fig 9 Baxi Gas Stoves 17 SERVICING ...

Page 18: ...E DOOR GLASS If necessary the glass can be removed as follows Step 1 Remove the trim by pressing on the curved edge at the top until the trim can be disengaged from the lugs Step 2 Slide the two glass retainer clips on one side only inwards towards the centre of the door as far as they will go Step 3 Pull this side of the glass away from the door casting easing the tags on the glass retaining clip...

Page 19: ...r upwards this will lift the door off of its hinges Step 2 Remove the old door seal and old adhesive using a wire brush ensuring that the surface is clean and dust free Step 3 Apply the new adhesive to the door casting Step 4 Starting at one end press the new door seal into the adhesive continue around the door making sure that the two ends of the seal are touching Cut off any excess seal Step 5 A...

Page 20: ...See note under Coal set on page 4 Step 6 Inspect the pilot assembly to ensure that it is clean unobstructed and in good order Step 7 Check system for gas soundness Step 8 Replace the coal set as described in arranging the coals CLEANING OUTER SURFACES To clean the outside first the appliance must be cold The outside finish of the fire is a durable high temperature paint It is best cleaned by using...

Page 21: ...rmocouple o k No Is the flue blocked Carry out smoke test Is their a spark at the electrode No Is pilot injector obstructed Clean No No No Turn gas on Purge system Yes Correct pressure No Correct alignment or replace No Yes Check piezo igniter Yes Check to ensure the pilot assy is not obstructed or faulty Yes No Has spillage monitoring system been activated Yes Investigate flue systems Yes No Chec...

Page 22: ...omplete Furness and Burnmoor range Paint Matching aerosol paint to tone in any connecting flues pipes or surrounding metalwork Add on Canopies Furness Low available only Size 405mm wide x 335mm deep Raises the fire approximately 150mm Burnmoor High and low are available Size 475mm wide x 345mm deep High Raises the fire approximately 240mm Low Raises the fire approximately 180mm 22 Baxi Gas Stoves ...

Page 23: ...AFS090 AFS091A AFS091 AFS1042 AFS1042 AFS047 AFS047 1a Becton Furness Coal Set 2 Co pilot Assembly 3 Elbow Injector 4 Gas Control Valve 5 Control Door Magnet 6 Hinge Kit To Fit Both Doors Comprises 2 Hinges 4 Fixings Per Set Part Description Visual Aid not to scale Baxi Furness Part No Baxi Burnmoor Part No ...

Page 24: ... AFGS037B AFS069 AFS088 8 Control Door Handle Assembly 9 Burner Fixing 10 Pipe Set Complete With Connectors 11 Decorative Door Surround 12 Main Door Assembly Complete With Handle Glass Gaskets Clips and Seal 13 Glass Replacement Kit Complete With Glass Gaskets Clips Part Description Visual Aid not to scale Baxi Furness Part No Baxi Burnmoor Part No ...

Page 25: ...GS105 AFGS106 15 Hotplate 16 Flue Outlet Spigot 17 Fire Door Rope Kit With Door Rope Glue Part Description Visual Aid not to scale Baxi Furness Part No Baxi Burnmoor Part No AFGS082 18 Flue spigot and hot plate gasket 19 Reflective Panels AFGS1071 20 Large Ceramic Panel AFGS093 AFGS093 AFGS062 AFGS1071 ...

Page 26: ... Stoves SPARE PARTS AFGS094 AFGS094 AFGS025 AFGS025 22 Gas Tap Part Description Visual Aid not to scale Baxi Furness Part No Baxi Burnmoor Part No 21 Small Ceramic Panel 23 Fire Door Locking Handle AFGS104 AFGS104 ...

Page 27: ... manual please contact your Baxi retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits as they will complete the service record chart Baxi Gas Stoves 27 SERVICE RECORD Date of Visit Company Work Carried Out Signature ...

Page 28: ...CHURE Model Serial No I ve checked it and it s O K Assembled by Checked by Date of Purchase Name and address of supplier Please ensure installer completes INSTALLATION CHECK LIST details on page 16 of this manual Please ensure the enclosed registration card is completed and returned to Baxi and the following information completed for your own information ...