GAS CONSUMPTION
Has a maximum natural gas input of 5.6kW (Gross)
Has a maximum natural gas output of 4.0kW
Has a minimum natural gas input of 1.57kW (Gross)
Has a minimum natural gas output of 1.0kW
OPERATING YOUR FIRE
The Oxysafe flame sensing and flue blockage safety system.
For your safety, this appliance is fitted with a flue blockage safety device that will shut
down the appliance in the event of abnormal flue conditions.
This device is NOT a
substitute for an independently mounted Carbon Monoxide detector.
The device will also automatically shut off the gas supply to the fire if the pilot flame
goes out due to lack of oxygen or for any other reason.
If this device starts to repeatedly shut off the gas, get expert advice.
This device incorporates a probe that senses that the heat from the pilot flame is correct.
If this probe is cool, the device will prevent any gas flow unless the control knob is held
down at the ignition position.
If, for any reason, the flames go out when the fire is hot or if the fire is turned off when
hot, always
wait at least three minutes before attempting to relight
.
To light the fire (Manual ignition).
The control is shown in Figure 2.
!
Depress the control knob and turn anticlockwise
towards the 1/IGN position. A spark should be
generated at the pilot while turning. The spark should
ignite the pilot.
If it does not
, keeping the knob
depressed, continue to turn the knob anticlockwise. A
second
spark should ignite the pilot. The pilot flame
can be seen through the opening immediately below
the right hand centre radiant (See figure 3).
Page 7
OWNER GUIDE
©
Baxi Heating U.K. Limited 2006.
PLEASE NOTE
When operating your fire for the first time, some vapours may be given off which may
cause a slight odour and could possibly set off any smoke alarms in the immediate
vicinity. These vapours are quite normal with new appliances. They are totally harmless
and will disappear after a few hours use.
Figure 2.