REPLACING THE RADIANTS
(See figure 4).
Always use the correct type of replacement radiant. Ask for Baxi Fires Division
part number 5110472. Turn the fire off and allow it to cool before attempting to
remove the radiants
.
To remove the dress guard, gently pull the centre of the dress guard with one hand and
carefully spring out one end of the dress guard with the other. Slide the other side of the
dress guard clear of the fixing holes. Take care not to scratch the trim.
Lift the radiant upward to clear the
metal retaining bar then pull out
bottom first.
Fit the new radiant by inserting its top
under the top lip of the radiant box
then swing the bottom of the radiant
over and behind the retaining bar.
It is
important that the front face of the
radiant should rest against the front
of the retaining channel.
Replace the
dress guard. To do this locate one side
of the dress guard into the two side
fixing holes. Spring the dress guard
slightly and locate into the opposite
fixing holes. Take care not to scratch
the trim.
MAINTENANCE
Battery replacement (Electronic ignition).
1.
The battery cover is located at the base of the fire on the right hand side.
2.
To access the battery cover the fascia will have to be removed. The fascia securing
screws are located at the bottom rear of the fascia. Remove the securing screws from
both sides of the fascia.
3.
Remove the control knob. To do this firmly hold the control knob and lift clear of the
fascia.
4.
The fascia can now be removed. To do this firmly hold the fascia sides, gently pull
the bottom of the fascia forward whilst lifting the fascia upward and forward. Place the
fascia in a safe place.
5.
Unscrew the battery cover in an anticlockwise direction.
6.
Remove the battery and discard.
Page 10
OWNER GUIDE
©
Baxi Heating U.K. Limited 2006.