3
TECHNICAL AND DIMENSIONAL CHARACTERISTICS
3.1
DESCRIPTION
Wood is an alternative source of energy
and it is also precious; therefore, use it in
the best way using suitable technologies for
combustion.
Iron cast and traditional combustion wood
boilers
BPI-Eco
are designed to ensure
maximum thermal yield optimising draught.
The boilers are in compliance with PAD
Directive 97/23/EEC and Standard EN
303-5.
347
392
211
P
ø 1
4
7
10
0
1
L
500
176
=
=
19
2
15
5
825
1
023
M
S
R
3.2
OVERALL DIMENSIONS (fig. 2)
Fig. 2
M
C.H. flow 2” (UNI-ISO 7/1)
R
C.H. return 2” (UNI-ISO 7/1)
S
Boiler drain 1/2” (UNI-ISO 7/1)
Fig. 3
1
2
3
4
0
5
10
15
20
Portata m
3
/h
∆
p mbar
1.250
1.450
1.650
5
1.550
1.350
25
30
35
3.4
HEAD LOSSES (fig. 3)
31
3.3
TECHNICAL FEATURES
BPI-Eco
1.250
1.350
1.450
1.550
1.650
Coal-fired thermal output
kW
23.0
34.0
45.0
56.0
67.0
Maximum power at wood
kW
20.0
30.0
40.0
49.0
58.0
Wood load thermal output
kW
14.0
20.5
27.5
34.0
40.0
Performance class EN 303-5
1
1
1
1
1
Duration of a coal-fired
h
≥
4
≥
4
≥
4
≥
4
≥
4
Duration of a wood load
h
≥
2
≥
2
≥
2
≥
2
≥
2
Load volume
dm
3
42,7
66,4
90,2
113,9
137,7
Minimum chimney depression
mbar
0.08
0.10
0.12
0.13
0.15
Dimensions
P (depth)
mm
425
575
725
875
1025
L (combustion chamber depth)
mm
346
496
646
796
946
Number of elements
n°
3
4
5
6
7
Max. operating temperature
°C
95
95
95
95
95
Min. temperature of water returned to the plant
°C
50
50
50
50
50
Max working pressure
bar
4
4
4
4
4
Test pressure
bar
6
6
6
6
6
Boiler capacity
l
30
39
48
57
66
Weight
kg
226
288
350
412
474
Flow rate m
3
/h
Summary of Contents for BPI-Eco 1.250