Renewal Firefront – Page 13
It is important that the existing installation is correct and that
the flue is performing satisfactorily. Any remedial work
Boiler Modification
necessary should be completed before the new appliance is
commissioned. Please read the Important Information
Section on page 3.
WARNING: When a renewal firefront is installed with a
Bermuda 401, 552, 45/3 or 57/3 which does not have an
Atmospheric Sensing Device filled the combined
appliance will not shut down under adverse flue
conditions. (When the fire is used without the boiler on,
the Atmospheric Sensing Device will operate).
NOTE:
A permanent live is required for correct operation of
the firefront.
Additional Installation Instructions
Bermuda SL3 Renewal G.C.No 37 075 02A
The kit supplied with Renewal appliances provides all the
necessary components to fit a Baxi Bermuda SL3 Renewal
firefront to the following Bermuda Boilers.
The Renewal Fires may be used with the following Boilers:
NOTE: It Is Important at this stage to fit the controls
Bermuda 401
G.C.No 44 077 49
heat shield supplied with the fire unit to the boiler front
Bermuda 552
G.C.No 44 077 50
panel.
Bermuda 45/3 M
G.C.No 44 077 61
Bermuda 45/3 E
G.C.No 44 077 60
Remove and discard the controls heat shield provided with
Bermuda 57/3 M
G.C.No 44 077 63
the boiler and fit the new controls heat shield using the
Bermuda 57/3 E
G.C.No 44 077 62
screws previously removed.
Bermuda 45/4 M
G.C.No 44 077 71
Bermuda 45/4 E
G.C.No 44 077 73
Check the data badge on the back boiler. If the boiler
Bermuda 57/4 M
G.C.No 44 077 72
internal wiring is not depicted, take the foil label from the kit
Bermuda 57/4 E
G.C.No 44 077 74
and attach it below the data badge art the boiler front door.
Existing Fire – Page 13
REMOVING THE EXISTING FIRE
Isolate the gas and electrical supply, including any
permanent live, to the combined appliance. Remove the
controls cover panel from the front of the fire.
Remove the tap control knob. Disconnect the electrical
socket from the fire plug if fitted. Remove the screws
securing the outercase to the innercase. Lift off the
outercase.
Turn the gas service tap to the “Boiler only” position by
turning ¼ turn clockwise.
Remove the radiants if fitted.
Disconnect the supply pipe at the fire inlet.
Remove any screws securing the fire to the wall. Pull the fire
forward until the flue spigot is clear of the boiler hood and lift
away.
Remove and discard the fire supply pipe from the service
gas tap. Disconnect and discard any electrical wiring
between the boiler input terminal and the fire.
If a radiant firefront has been installed previously it will be
necessary to unscrew and remove the extension plate from
the boiler controls heat shield. Once removed this item can
be discarded.