3.0 Operating the Boiler
5
3.1
To light the boiler
(Fig. 2 & 2a)
Ensure that all external controls, e.g. room
thermostat, timer etc., are calling for heat. To
operate the pilot turn the thermostat knob to the
desired position. The pilot light (50/4E) or indicator
light (50/5) will illuminate once the pilot is lit. The
burner will also light shortly after the pilot has been
established. The pilot is intermittent and only lights
when there is a call for heat.
If the boiler cannot be lit by the above method
consult your Service Engineer.
3.2
To adjust the boiler temperature
(Fig. 2 & 2a)
Turn the boiler thermostat knob clockwise to the
required setting. The optimum boiler thermostat
setting depends upon type of system, external
controls and your requirements. Your Installer will
be able to advise you on this matter.
3.3
Resetting the boiler
1.
Inset 2 Boiler 50/4 E Model
(Fig. 2). If the
boiler lockout light is illuminated, it is necessary to
reset the appliance. To do this turn the boiler
thermostat control knob fully anticlockwise to the
OFF position and wait 10 seconds. Turn the
control knob clockwise to the required setting. the
boiler will commence the ignition sequence
providing the water temperature is sufficiently cool.
2
. Inset 3 Boiler 50/5 Model
(Fig. 2a). If the
indicator light is illuminated red/or flashing red, it is
necessary to reset the appliance. To do this turn
the boiler thermostat control knob fully anti-
clockwise to the OFF position and wait until the
light shows orange. Turn the control knob
clockwise to the required setting. The boiler will
commence the ignition sequence.
3.4
To switch off the boiler for short
periods
(Fig. 2 & 2a)
1. Turn the boiler thermostat knob fully anti-
clockwise to the off position (O) until it clicks.
3.5
To switch off the boiler for long
periods
(Fig. 2 & 2a)
1. Turn the boiler thermostat knob fully anti-
clockwise to the off position (O) until it clicks.
2. It is recommended that if the system is left off
for long periods during cold weather the whole
system is drained to avoid frost damage.
3. Advice on draining the system can be obtained
from your Service Engineer.
Controls Access Door
Boiler Controls
Pilot Viewing Window
Boiler Thermostat
Knob
Gas Service Cock
50/5
Boiler Controls
Indicator Light
Fig. 2a
Pilot Viewing Window
Boiler Thermostat
Knob
Gas Service Cock
50/4 E
Boiler Controls
Boiler Lockout Light
Green Pilot Light
Fig. 2