3.0 Operating the Boiler

5

3.1

To light the boiler 

(Fig. 2 & 2a)

Ensure that all external controls, e.g. room

thermostat, timer etc., are calling for heat. To

operate the pilot turn the thermostat knob to the

desired position. The pilot light (50/4E) or indicator

light (50/5) will illuminate once the pilot is lit. The

burner will also light shortly after the pilot has been

established. The pilot is intermittent and only lights

when there is a call for heat.

If the boiler cannot be lit by the above method
consult your Service Engineer.

3.2

To adjust the boiler temperature 

(Fig. 2 & 2a)

Turn the boiler thermostat knob clockwise to the

required setting. The optimum boiler thermostat

setting depends upon type of system, external

controls and your requirements. Your Installer will

be able to advise you on this matter.

3.3

Resetting the boiler

1.

Inset 2 Boiler 50/4 E Model

(Fig. 2). If the

boiler lockout light is illuminated, it is necessary to

reset the appliance. To do this turn the boiler

thermostat control knob fully anticlockwise to the

OFF position and wait 10 seconds. Turn the

control knob clockwise to the required setting. the

boiler will commence the ignition sequence

providing the water temperature is sufficiently cool.

2

. Inset 3 Boiler 50/5 Model

(Fig. 2a). If the

indicator light is illuminated red/or flashing red, it is

necessary to reset the appliance. To do this turn

the boiler thermostat control knob fully anti-

clockwise to the OFF position and wait until the

light shows orange. Turn the control knob

clockwise to the required setting. The boiler will

commence the ignition sequence.

3.4

To switch off the boiler for short 
periods 

(Fig. 2 & 2a)

1. Turn the boiler thermostat knob fully anti-

clockwise to the off position (O) until it clicks.

3.5

To switch off the boiler for long 
periods 

(Fig. 2 & 2a)

1. Turn the boiler thermostat knob fully anti-

clockwise to the off position (O) until it clicks. 

2. It is recommended that if the system is left off

for long periods during cold weather the whole

system is drained to avoid frost damage. 

3. Advice on draining the system can be obtained

from your Service Engineer.

Controls Access Door

Boiler Controls

Pilot Viewing Window

Boiler Thermostat

Knob

Gas Service Cock

50/5
Boiler Controls

Indicator Light

Fig. 2a

Pilot Viewing Window

Boiler Thermostat

Knob

Gas Service Cock

50/4 E
Boiler Controls

Boiler Lockout Light

Green Pilot Light

Fig. 2

Summary of Contents for Bermuda Inset 3 BB Super

Page 1: ...Inset 3 Super Fireside Gas Central Heating Units User s Operating Instructions Please keep these instructions safe Should you move house please hand them over to the next occupier TS BS KS SC Super FS BB CB BC Super ...

Page 2: ...Baxi Bermuda Inset 3 Boiler 50 5 G C No 44 075 07 Baxi is a BS EN ISO 9001 Accredited Company IMPORTANT Installation Commissioning Service Repair This appliance must be installed in accordance with the manufacturer s instructions and the regulations in force Read the instructions fully before installing or using the appliance In GB this must be carried out by a competent person as stated in the Ga...

Page 3: ...e serviced annually Your Installer will be able to advise you Guarding This appliance has a naked flame and a fireguard conforming to B S 6539 or 6778 should be used especially in instances where young children the elderly or infirm are likely to be present Never Hang Flammable Items Over The Appliance Notice Discolouration of wall surfaces Most heating appliances generate warm air convection curr...

Page 4: ...ontrols access door at the bottom of the fire to gain access to the boiler controls 3 Fire identification is situated on the inner right hand side panel behind the controls access door 4 Boiler identification is on the boiler controls behind the controls access door 5 Before operating the unit ensure that the main gas and electricity supplies are turned on 2 3 Pilot A S D 1 Both the boiler and fir...

Page 5: ...ckwise to the required setting the boiler will commence the ignition sequence providing the water temperature is sufficiently cool 2 Inset 3 Boiler 50 5 Model Fig 2a If the indicator light is illuminated red or flashing red it is necessary to reset the appliance To do this turn the boiler thermostat control knob fully anti clockwise to the OFF position and wait until the light shows orange Turn th...

Page 6: ...pressed and held for less than 3 seconds the fire will not ignite This is a built in safety feature 4 If the fire fails to ignite or goes out at any time switch the fire off and repeat the procedure 5 If you require the fire on the high setting press the High Low button The green high setting indicator will come on to confirm this This operation can be undertaken during the ignition sequence NOTE ...

Page 7: ...s all the loose coals side cheeks rear and front coals are to be fitted If not all the coals require replacement refer to the diagrams and determine at which point you need to commence 3 Place the right left hand side cheeks against the combustion box side walls Fig 4 4 Locate the rear coal behind the combustion box base front lip and angle it back against the side cheek location stops Figs 4 5 5 ...

Page 8: ...ouching the fuel effect pieces is required Always wash hands thoroughly after handling the fuel effect pieces 6 2 Changing the Bulbs IMPORTANT Only replace the bulb s with a 12V 20W halogen capsule bulb available at most DIY outlets specialist electrical stores or from Baxi 1 Remove the coals placing them on a newspaper or similar to prevent soiling furnishings 2 Lift out the glass retaining assem...

Page 9: ...leted for the customer who is the original user 3 To maximise the benefit from our guarantee we urge you to return the reply paid guarantee registration 4 This does not in any way prejudice your rights at Common Law Such rights between the customer and the installer or supplier from whom the unit was purchased remain intact Any component or part which becomes defective during the guarantee period ...

Page 10: ...8 0 Notes 10 ...

Page 11: ...r the domestic heating market Gas Central Heating Boilers Wall Floor and Fireside models Independent Gas Fires Renewal Firefronts Gas Wall Heaters Solid Fuel Fires If you require information on any of these products please write to the Sales Department 11 ...

Page 12: ...Comp No 247853 Iss 4 12 02 B A X I P O T T E R T O N Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN After Sales Service 08706 096 096 Technical Enquiries 08706 049 049 www baxi co uk ...

Reviews: