background image

2

Baxi is one of the leading  manufacturers of domestic

heating products in the UK. 

Our first priority is to give a high quality service to our

customers. Quality is built into every Baxi product -

products which fulfil the demands and needs of

customers, offering choice, efficiency and reliability. 

To keep ahead of changing trends, we have made a

commitment to develop new ideas using the 

latest technology -  with the aim of continuing to 

make the products that customers want to buy. 

Everyone who works at Baxi has a commitment to

quality because we know that satisfied customers

mean continued success.

We hope you get a satisfactory service from Baxi. If

not, please let us know.

Natural Gas

Baxi Bermuda Inset 3 BS Super

G.C.No. 37 075 56 

Baxi Bermuda Inset 3 TS Super

G.C.No. 37 075 57

Baxi Bermuda Inset 3 KS Super

G.C.No. 37 075 54

Baxi Bermuda Inset 3 FS Super

G.C.No. 37 075 55

Baxi Bermuda Inset 3 BB Super

G.C.No. 37 075 62

Baxi Bermuda Inset 3 CB Super

G.C.No. 37 075 63

Baxi Bermuda Inset 3 SC Super

G.C.No. 37 075 64

Baxi Bermuda Inset 3 BC Super

G.C.No. 37 075 65

For use with the following boiler:

Baxi Bermuda Inset 2 Boiler 50/4 E

G.C.No. 44 075 03

Baxi Bermuda Inset 3 Boiler 50/5

G.C.No. 44 075 07

Baxi is a BS-EN ISO 9001
Accredited Company

IMPORTANT - Installation, Commissioning,
Service & Repair

This appliance must be installed in accordance with
the manufacturer’s instructions and the regulations
in force. Read the instructions fully before installing
or using the appliance.

In GB, this must be carried out by a competent
person as stated in the Gas Safety (Installation &
Use) Regulations. 

Definition of competence: A person who works for a
CORGI registered company and holding current
certificates in the relevant ACS modules, or valid
ACoP equivalents, is deemed competent.

In IE, this must be carried out by a competent
person as stated in I.S. 813 “Domestic Gas
Installations”.

Codes of Practice,

most recent version

should be used

In GB the following Codes of Practice apply:
Standard

Scope

BS 6891

Gas Installation.

BS 5440 Part 1

Flues.

BS 5440 Part 2

Ventilation.

BS 5871 Part 2

Installation of inset live fuel effect fires. 

In IE the following Codes of Practice apply:
Standard

Scope

I.S. 813

Domestic Gas Installations.

IMPORTANT

- The addition of anything that may

interfere with the normal operation of the
appliance without express written permission
from the manufacturer or his agent could
invalidate the appliance warranty. In GB this
could also infringe the 

G

AS

S

AFETY

(Installation

and Use) 

R

EGULATIONS

.

Summary of Contents for Bermuda Inset 3 BB Super

Page 1: ...Inset 3 Super Fireside Gas Central Heating Units User s Operating Instructions Please keep these instructions safe Should you move house please hand them over to the next occupier TS BS KS SC Super FS BB CB BC Super ...

Page 2: ...Baxi Bermuda Inset 3 Boiler 50 5 G C No 44 075 07 Baxi is a BS EN ISO 9001 Accredited Company IMPORTANT Installation Commissioning Service Repair This appliance must be installed in accordance with the manufacturer s instructions and the regulations in force Read the instructions fully before installing or using the appliance In GB this must be carried out by a competent person as stated in the Ga...

Page 3: ...e serviced annually Your Installer will be able to advise you Guarding This appliance has a naked flame and a fireguard conforming to B S 6539 or 6778 should be used especially in instances where young children the elderly or infirm are likely to be present Never Hang Flammable Items Over The Appliance Notice Discolouration of wall surfaces Most heating appliances generate warm air convection curr...

Page 4: ...ontrols access door at the bottom of the fire to gain access to the boiler controls 3 Fire identification is situated on the inner right hand side panel behind the controls access door 4 Boiler identification is on the boiler controls behind the controls access door 5 Before operating the unit ensure that the main gas and electricity supplies are turned on 2 3 Pilot A S D 1 Both the boiler and fir...

Page 5: ...ckwise to the required setting the boiler will commence the ignition sequence providing the water temperature is sufficiently cool 2 Inset 3 Boiler 50 5 Model Fig 2a If the indicator light is illuminated red or flashing red it is necessary to reset the appliance To do this turn the boiler thermostat control knob fully anti clockwise to the OFF position and wait until the light shows orange Turn th...

Page 6: ...pressed and held for less than 3 seconds the fire will not ignite This is a built in safety feature 4 If the fire fails to ignite or goes out at any time switch the fire off and repeat the procedure 5 If you require the fire on the high setting press the High Low button The green high setting indicator will come on to confirm this This operation can be undertaken during the ignition sequence NOTE ...

Page 7: ...s all the loose coals side cheeks rear and front coals are to be fitted If not all the coals require replacement refer to the diagrams and determine at which point you need to commence 3 Place the right left hand side cheeks against the combustion box side walls Fig 4 4 Locate the rear coal behind the combustion box base front lip and angle it back against the side cheek location stops Figs 4 5 5 ...

Page 8: ...ouching the fuel effect pieces is required Always wash hands thoroughly after handling the fuel effect pieces 6 2 Changing the Bulbs IMPORTANT Only replace the bulb s with a 12V 20W halogen capsule bulb available at most DIY outlets specialist electrical stores or from Baxi 1 Remove the coals placing them on a newspaper or similar to prevent soiling furnishings 2 Lift out the glass retaining assem...

Page 9: ...leted for the customer who is the original user 3 To maximise the benefit from our guarantee we urge you to return the reply paid guarantee registration 4 This does not in any way prejudice your rights at Common Law Such rights between the customer and the installer or supplier from whom the unit was purchased remain intact Any component or part which becomes defective during the guarantee period ...

Page 10: ...8 0 Notes 10 ...

Page 11: ...r the domestic heating market Gas Central Heating Boilers Wall Floor and Fireside models Independent Gas Fires Renewal Firefronts Gas Wall Heaters Solid Fuel Fires If you require information on any of these products please write to the Sales Department 11 ...

Page 12: ...Comp No 247853 Iss 4 12 02 B A X I P O T T E R T O N Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN After Sales Service 08706 096 096 Technical Enquiries 08706 049 049 www baxi co uk ...

Reviews: