Supplied By www.heating spares.co Tel. 0161 620 6677
page 9
Fig. 12a
Fig. 13 The Fire
Appliance Details
B
ERMUDA
GF3 S
UPER
Height - 706mm (to hearth)
(see Site Requirements
Width - 750mm
for clearances)
Depth - 326mm
Weight - 35.8kg (unpacked)
B
ERMUDA
LFE5 S
UPER
Height - 713mm
(see Site Requirements
Width - 915mm
for clearances)
Depth - 301mm
Weight - 39.1kg (unpacked)
H
EAT
I
NPUT
(G
ROSS
)
5.70kW (19,450 Btu/h)
H
EAT
O
UTPUT
3.69kW (12,590 Btu/h)
G
AS
G
ROUP
G20 (Natural Gas)
I
NJECTOR
S
IZE
GF3
230 F11
LFE5 F13
S
ETTING
P
RESSURE
GF3
14.5 + 0.5mbar
(Cold)
(5.8 + 0.2in wg)
S
ETTING
P
RESSURE
LFE5
13.8 + 0.5mbar
(Cold)
(5.5 + 0.2in wg)
T
HERMOCOUPLE
O
UTPUT
9.4 - 13mV
P
ILOT
A
SSY
GF3
9402
LFE5 9401
H
EAT
I
NPUT
(G
ROSS
)
210W (715 Btu/h)
GF3 Super
LFE5 Super
Gas Control
Knob
Gas Control
Knob
Controls Cover Panel
Controls Cover Panel
6. PILOT/A.S.D. ASSEMBLY
(Fig. 12a)
WARNING:
The A.S.D. pilot assembly should not be
adjusted in any way. The A.S.D. shall not be altered so
that it will not operate or bypassed in any way. The
thermocouple cannot be changed as an individual
component.The complete assembly must be replaced in
the event of one or other component failure(s).
Only use a Genuine Baxi Spare Part.
Undo the screw retaining the pilot shield, and remove the
shield. Pull back the sleeve and disconnect the lead from
the electrode. Undo the nut on the pilot feed pipe.
Remove the screw holding the assembly to the
bracket. Undo the thermocouple from the gas tap.
Remove the assembly from the fire.
On re-assembly, shape the thermocouple in a similar
manner to the original.
7. ELECTRO-MAGNET UNIT
(Figs 10 & 12)
(a) Remove the gas tap as explained in 1(b).
(b) Remove the electro-magnet retaining nut and
withdraw the electro-magnet unit.
8. PIEZO UNIT
(Fig.12)
Pull off the plastic cap and disconnect the spark electrode
lead from the piezo unit. Undo the tabs on the rear of the
piezo unit and remove. Replace the piezo unit twisting the
tabs to retain it firmly in position. Re-connect the spark
electrode lead and re-fit the plastic cap.
9. LIGHT SWITCH
Caution:
Ensure electrical supply is isolated.
Pull off the two flag terminals from the switch. Press
together the retaining arms on the rear of the switch and
remove the switch. Replace the switch and terminals, see
illustrated wiring diagram.
10. RESISTOR
(a) Check that the electrical supply is isolated.
(b) Remove the two screws securing the light bulb cover
and lift upwards.
(c) Remove the clip securing the resistor to the cover and
disconnect the 2 wires.
(d) Replace the resistor and reassemble in reverse order.
Electrical Supply 230V 50Hz 110W.
Fig. 12 Gas Control Tap/Flame Failure Device
Piezo Igniter
Igniter
Retaining
Screws
F.F.D./Electro-Magnet Unit
Gas Tap Body
with Plug
Fig. 11 Coal Bed
Coal Bed Locating
Pins (2 off)
Burner Securing
Screws (2 off)
Pilot Shield
Glass Front
Panel
Support Bar
Spark
Electrode
Glass Front Panel
Retaining Clamps
Glass Front Panel
Sealing Rope
Rope Seal
Retaining Barbs
Pilot &
Thermocouple