INSTALLATION - Page 18
3
For installations requiring a permanent live ie:-
where the firefront is equipped with either lighting
effects or lighting effects and electronic ignition
proceed as follows:-
Connect the inlet supply cable(s) as indicated:-
Permanent live to
L
Controls system switched live to
SL
Control system neutral to
N
Earth to
4
The circular part of the ring terminal on the earth wire must
be detached.
Remove the side cable clamp and connect the wire from the
fire front kit as indicated:-
Brown (live) to
L
Blue (neutral) to
N
Green and yellow (earth) to
5
Re-fit both cable clamps ensuring that the outer insulation is
securely held and re-fit the socket cover.
For installations not requiring a permanent live
ie: radiant fire fronts proceed as follows:-
Connect the inlet supply cable as indicated:-
Control system switched live to
SL
Control system neutral to
N
Earth to
Using the wire provided in the kit, link SL to L.
Re-fit the cable clamp ensuring that the outer insulation is
securely held and refit the socket Cover.
Ensure that all cables are routed away from the
boiler casing and hood.