3.3
Technical data
Tab.1
Unit
AS 300–2E BC
Primary circuit: Solar exchanger
Maximum operating temperature
°C
110
Maximum operating pressure
MPa (bar)
1.0 (10)
Exchanger capacity
litres
6.7
Exchange surface
m
2
1.2
Pressure drop at 1 m
3
/h
kPa
3.1
Primary circuit: Back-up exchanger
Maximum operating temperature
°C
110
Maximum operating pressure
MPa (bar)
1.0 (10)
Exchanger capacity
litres
13.2
Exchange surface
m
2
2.4
Pressure drop at 2 m
3
/h
kPa
19.2
Secondary circuit (domestic water)
Maximum operating temperature
°C
110
Maximum operating pressure
MPa (bar)
1.0 (10)
Water capacity
litres
300
Weight
Shipping weight - Tank package
kg
140
Primary circuit performances: Back-up exchanger
Output exchange
kW
25.5
Performance
Hourly flow rate (ΔT = 35 °C)
litres/h
626
Standby heat loss (ΔT=45K)
kWh/24h
2.10
(1) Primary temperature: 55 °C - Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary flow rate: 2 m
3
/h
Tab.2
Technical parameters for hot water storage tank
Product name
Unit
AS 300–2E BC
Storage volume
V
litres
300
Standing loss
S
W
88
3 Description of the product
12
AS 300–2E BC
7724479 - v03 - 07102019