2

© Baxi Heating UK Ltd 2009

CE Marking

This product is CE marked and conforms to the essential requirements of the following
Directives:

- Low voltage no. 73/23 EEC, modified 93/68 EEC.
- Electromagnetic Compatibility no. 891336 EEC, modified 92/31 and 93/68 EEC.

Electrical equipment is in accordance with standard EN 60 335-2-40

The following standards and directives should also be considered when installing this unit.
Current Wiring Redulations BS 7671
HVAC TR/30 Guide to good practice - Heat pumps 
BS EN 15450: 2007 Heating systems in buildings - Design of heat pump heating systems 
EC Regulation No 842/2006 on certain fluorinated greenhouse gases: Supplementary guidance
for stationary refrigeration air conditioning and heat pumps

© Baxi Heating UK Ltd 2009 

All rights reserved. No part of this publication may be reproduced or transmitted in any form or by

any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical,
recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under
Copyrights, Designs and Patents Act 1988.

Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made,

giving details of the proposed use, to the following address:

The Company Secretary, Baxi Heating UK Ltd, The Wyvern Business Park, Stanier Way, Derby, DE21 6BF.

Full acknowledgement of author and source must be given.

WARNING:

Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and

civil claims for damages.

ISO 9001

FM 00866

Summary of Contents for Ambiflo

Page 1: ... Baxi Heating UK Ltd 2009 AmbifloTM Heat Pump System 7kW to 10 5kW Inclusive Air to Water Heat Pump for Outdoor Installation User s Operating Instructions ...

Page 2: ...ps Baxi Heating UK Ltd 2009 All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means or stored in any retrieval system of any nature including in any database in each case whether electronic mechanical recording or otherwise without the prior written permission of the copyright owner except for permitted fair dealing under Copyrights Designs and ...

Page 3: ...3 Baxi Heating UK Ltd 2009 CONTENTS 1 0 General Information 4 2 0 Introduction 5 3 0 Operating the Appliance 6 4 0 Other Information 9 5 0 Notes 11 Section Page ...

Page 4: ...of the unit and an explanation of the controller s icons and functions Defrosting of the Unit Occasionally frost will form on the rear of the unit across the finned heat exchanger This is a normal function of the Heat Pump s operation and should not cause concern to the user This function is performed automatically by the unit as and when necessary During the defrosting phase water vapour may be s...

Page 5: ...re heating in your home For every unit of electrical energy used several units of heat are delivered So relating the energy purchased to the energy delivered heat pumps are extremely efficient 2 2 Domestic Hot Water 1 Please note that an auxiliary source of heat is required for your domestic hot water such as an electric immersion heater for example 2 3 Electrical Heater 1 When the outside tempera...

Page 6: ...essure is below this top up the system using the filling point provided If you are unsure of its position or cannot identify it contact your installer who fitted the Heat Pump 3 2 Operating the Time and Temperature Controller 1 The Baxi AmbifloTM Heat Pump has been configured to work at its optimum efficiency by your commissioning engineer and the external settings should not be altered 2 The heat...

Page 7: ...o be individually set as the timings cannot be copied across 7 If a second heating zone is part of the system turn the Aquaset dial to Z2 Fig 2 item 9 and repeat the above procedure for heating Zone 2 3 6 Adjustment of the Return Water Temperature to compensate for excessive heating or cooling 1 Turn the dial on the Aquaset controller to the OFF position Fig 2 item 6 2 Press and hold the and butto...

Page 8: ... tiio on ns s a an nd d d do o n no ot t iin nd diic ca at te e a a f fa au ullt t A A f flla as sh hiin ng g d diis sp plla ay y w wiit th ho ou ut t a an n a alla ar rm m c co od de e iin nd diic ca at te es s t th ha at t t th he e w wa at te er r r re et tu ur rn n t te em mp pe er ra at tu ur re e iis s b be ello ow w t th he e m miin niim mu um m s sa af fe e v va allu ue e C Co on nt ta ac ...

Page 9: ...nt of a fault 3 The pipework between the heat pump and the property can be hot The installer should have insulated these pipes This insulation is important for the safe operation of the unit so in the event of any damage contact your installer to arrange a repair Do not stand on the pipes around the Heat Pump unit as injury or damage may occur 4 If the electrical supply for the heat pump system is...

Page 10: ...it will be necessary to show that the routine maintenance has been carried out in accordance with the requirements specified in the Installation Instructions Failure to maintain the system may invalidate your warranty 4 5 Disposal 1 This unit must not be crushed or incinerated 2 The Baxi AmbifloTM Heat Pump contains a number of components that must be disposed of under controlled conditions Under ...

Page 11: ...11 5 0 Notes Baxi Heating UK Ltd 2009 ...

Page 12: ...ements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject to our standard Conditions of Sale which are available on request BAXI A Trading Division of Baxi Heating UK Ltd 3879156 A Division of Baxi Group Brooks House Coventry Road Warwick CV34 4LL Service support and Technical support 0844 871 1568 Website www baxi co uk e oe ...

Reviews: