17.0
Fault finding
46
© Baxi Heating UK Ltd 2011
17.1
Failures with error message
Some system failure modes can be recognised by the solar
differential temperature controller and will be
indicated by an error message on the controller display. Refer
to the table below for details of possible errors and suggested
measures to rectify.
Error representation on display Possible reasons
Measures
flashing
• Sensor wire broken
• Check wire
• Sensor defect
• Check sensor resistance, if necessary exchange sensor
flashing
• Short circuit in sensor wire
• Check wire
• Sensor defect
• Check sensor resistance, if necessary exchange sensor
• Error in pump connection
• Check cabling
• Pump defect
• Exchange pump
• Air in the system
• Check the float of the flow meter moves
when the system runs (if visible)
• Connection with flow
• Check wire
meter defect
• Sensor wire broken
• Check wire
• Sensor defect
• Check sensor resistance, if necessary exchange sensor
!
!
!
+
Circulation error: no flow
Additionally at energy
productivity measurement:
flashing