10
© Baxi Heating UK Ltd 2011
7.1
Installation
For the 10 tube addition, only one solar sensor is required. The
solar sensor should be placed in the last sensor pocket in
series. If one of the tube arrays is position such that more solar
gain would be achieved then the sensor should be located in
that manifold sensing pocket.
The Solar Collector temperature sensor should be installed in
the sensor pocket securely. The sensor with the black silicone
sheathing must be used in the solar collector pocket.
All materials used for installing temperature sensors (sensor
element, conducting compound, cables, sealing and insulating
materials) must be suitably temperature resistant (up to
200°C).
Solar Collector sensor may be extended (using the 13m
extension cable supplied).
The sensor may be extended up to 50m but 0.75mm
screened flex must be used.
7.0
Installation of collector sensor
Fig. 10