2

© Baxi Heating UK Ltd 2007

Natural Gas

Potterton Gold Combi 24 HE

G.C.N

o

47 590 05

Potterton Gold Combi 28 HE

G.C.N

o

47 590 06

Potterton Gold Combi 33 HE

G.C.N

o

47 590 19

© Baxi Heating UK Ltd 2007 

All rights reserved. No part of this publication may

be reproduced or transmitted in any form or by any means, or stored in any
retrieval system of any nature (including in any database), in each case whether
electronic, mechanical, recording or otherwise, without the prior written
permission of the copyright owner, except for permitted fair dealing under
Copyrights, Designs and Patents Act 1988.

Applications for the copyright owner’s permission to reproduce or make other
use of any part of this publication should be made, giving details of the proposed
use, to the following address:

The Company Secretary, Baxi Heating UK Ltd, Pentagon House, 
Sir Frank Whittle Road, Derby, DE21 4XA.

Full acknowledgement of author and source must be given.

WARNING:

Any person who does any unauthorised act in relation to a

copyright work may be liable to criminal prosecution and civil claims for damages.

Baxi Heating UK Ltd is a

BS-EN ISO 9001 Accredited Company

The code of practice for the installation,

commissioning & servicing of central

heating systems.

“Potterton” supports

1.0

Quick Reference Guide

3

2.0

Troubleshooting

4

3.0

Repressurising System

6

4.0

Clearances

7

5.0

Care of the Boiler

8

6.0

Legislation

9

7.0

Setting the Timer

10

8.0

Emergency

11

9.0

Warranty & Service

12

Section

Page

Contents

Boiler Controls - see opposite page

for Operating Quick Reference Guide

 

 

 

This product has an energy rating (A) on a scale of A to G.

For more information see www.boilers.org.uk. This is a certification mark.

Summary of Contents for 24

Page 1: ...Baxi Heating UK Ltd 2007 User s Guide and Important Warranty Information Gold Combi 24 28 33 HE Please keep these instructions in a safe place If you move house please hand them over to the next occupier ...

Page 2: ...e proposed use to the following address The Company Secretary Baxi Heating UK Ltd Pentagon House Sir Frank Whittle Road Derby DE21 4XA Full acknowledgement of author and source must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages Baxi Heating UK Ltd is a BS EN ISO 9001 Accredited Company Th...

Page 3: ...dicator The indicator will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water Boiler Output Temperature In either the central heating or domestic hot water position the display will illuminate showing the current boiler temperature in degrees centigrade ...

Page 4: ... on Reset Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure needle in the GREEN section between 1 and 2 5 bar If the reading falls below 1 bar repressurise the system as described in section 3 1 Does the display show an error code e g E133 E110 Boiler not working NO NO YES YES YES ...

Page 5: ...fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible YES NO CONTACTYOUR INSTALLER OR SERVICE ENGINEER YES 12 1 2 3 4 5 6 7 8 9 1 0 11 CH ON CH OFF Typical examples of external timer NO ...

Page 6: ... pressure falls below 0 5 this may indicate a leak on the central heating system Fig 2 Error Code E119 will be shown on the display 3 2 To Re Pressurise the System 1 The procedure is for the optional filling loop kit when fitted However even if your boiler has an external loop the principle is similar 2 Look at the boiler from underneath There will be two taps at the end of copper pipes one with a...

Page 7: ...arning labels on your boiler 6 Your boiler should have the following minimum clearances for Safety and Maintenance Fig 34 Top 200mm Bottom 200mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing 7 If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings 8 Flammable materials must not be stored in...

Page 8: ...E20 E28 E50 E125 E160 indicate faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 or E130 is displayed overheat of the primary water or flue system has occurred Turn the selector switch to the reset position and hold for at least 5 seconds If the boiler does not relight or the code is displayed regularly contact your instal...

Page 9: ... check online at www corgi gas safety com The boiler meets the requirements of Statutory Instrument The Boiler Efficiency Regulations 1993 No 3083 and is deemed to meet the requirements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0085 Product Production cer...

Page 10: ...c hot water will operate on demand To set the time of day Turn the timer outer bezel clockwise to align the pointer with the correct time to the nearest 15 minutes ensuring that A M P M is considered Do not at any time attempt to turn the bezel anti clockwise To set the timed heating program Decide which times of the day the central heating is required The heating will operate when the white tappe...

Page 11: ...ed until the fault has been corrected by a competent person Warning Gas Tap Heating Flow Heating Return and Mains Water Inlet Isolating Valves Fig 9 Fig 10 In an Emergency If a water or gas leak occurs or is suspected the boiler can be isolated at the inlet valves as follows 1 Using a suitable open ended spanner turn the square nut on the gas tap through 90 1 4 turn to isolate the gas supply at th...

Page 12: ... that you may need Our contact centre is open Monday to Friday 8am 6pm weekends and Bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling heateam it would be helpful if you could have the following information to hand 1 boiler serial number see opposite 2 boiler make and model number 3 Your installer name and address details 4 Proof of purchase if you do not have the boil...

Reviews: