background image

9.0 Warranty & Service

© Baxi Heating UK Ltd 2007

P O T T E R T O N

A   T r a d i n g   D i v i s i o n   o f   B a x i   H e a t i n g   U K   L t d

Brooks House, Coventry Road, Warwick. CV34 4LL
After Sales Service 08706 017 017 Technical Enquiries 08706 049 049
Website www.potterton.co.uk
e&oe

company

UK Comp N

o

5116283 - Iss 4 - 5/07

Information Label

All descriptions and illustrations provided in this leaflet have been carefully

prepared but we reserve the right to make changes and improvements in

our products which may affect the accuracy of the information contained in

this leaflet. All goods are sold subject to our standard Conditions of Sale

which are available on request.

Serial Number

Date of Installation

Installer Details (name, address and contact number(s))

Please complete the boxes below

D D

M

Y

Y

M

Standard Warranty Term & Conditions

3 Years Free Warranty - register today

To receive your 3 years free warranty please complete the form supplied with
the boiler or simply call 

heateam

, the service of Baxi Heating UK Ltd on 

08706 017 017.

Our promise to you

If you experience a fault with your new boiler, we aim to provide a safe and
high quality repair service supported by our dedicated national network of
highly skilled engineers. If your installer can’t resolve the problem for you, we
will do everything we can to get an engineer out to you as quickly as possible.
Nothing in this warranty will affect your statutory consumer rights.

What you need to do if you experience a problem with your heating system
or the operation of the boiler

You should always contact your installer first, because the fault may not be
related to the boiler. If your installer confirms that the fault is within the boiler
itself and he/she can’t repair it, our friendly customer service team is on hand
to help. Simply call our service division 

heateam

on 

08706 017 017

to book an

engineer visit or for any general advice that you may need. Our contact centre
is open Monday to Friday 8am - 6pm, weekends and Bank Holidays 8.30am -
2pm, excluding Christmas Day and New Years Day.

When calling 

heateam

it would be helpful if you could have the following

information to hand:-

1

boiler serial number (see opposite).

2

boiler make and model number.

3

Your installer name and address details.

4

Proof of purchase (if you do not have the boiler serial number).

What this warranty covers

Free of charge repair or replacement of components found to be faulty from
manufacture.

Free of charge replacement of the complete unit provided always that the
failure is related to a manufacturing fault that cannot be repaired or is
uneconomic to repair.

The warranty runs for 3 years from the date your product is installed.

What this warranty does not cover

Repairs to boilers which haven’t been installed and commissioned properly,
and as set out in the installation instructions (this includes the need to flush the
system effectively and add a suitable corrosion inhibitor).

Any damage caused by hard water scale deposits and/or aggressive water
resulting from corrosion.

Any other defects or failures, either in the connected heating system or
outside of the boiler itself.

Faults caused by inadequate supply of electricity, gas or water to the property.

Installations within commercial settings for which this boiler was not designed.

Reimbursement of any third party repair or replacement costs that we haven’t
been told about or agreed with you in advance.

Compensation for consequential losses (e.g. loss of earnings, business losses,
stress and inconvenience) arising from a production breakdown, including
repair delays caused by factors outside our reasonable control.

Annual Service

To ensure you receive the maximum efficiency from your boiler we
recommend your boiler has an annual service so you and your family can
continue to enjoy heating and hot water comfort. To arrange an annual service
from one of our Baxi Heating UK Ltd heating experts, please call to arrange a
visit convenient to you.

IT Comp No 925.349.1

Summary of Contents for 24

Page 1: ...Baxi Heating UK Ltd 2007 User s Guide and Important Warranty Information Gold Combi 24 28 33 HE Please keep these instructions in a safe place If you move house please hand them over to the next occupier ...

Page 2: ...e proposed use to the following address The Company Secretary Baxi Heating UK Ltd Pentagon House Sir Frank Whittle Road Derby DE21 4XA Full acknowledgement of author and source must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages Baxi Heating UK Ltd is a BS EN ISO 9001 Accredited Company Th...

Page 3: ...dicator The indicator will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water Boiler Output Temperature In either the central heating or domestic hot water position the display will illuminate showing the current boiler temperature in degrees centigrade ...

Page 4: ... on Reset Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure needle in the GREEN section between 1 and 2 5 bar If the reading falls below 1 bar repressurise the system as described in section 3 1 Does the display show an error code e g E133 E110 Boiler not working NO NO YES YES YES ...

Page 5: ...fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible YES NO CONTACTYOUR INSTALLER OR SERVICE ENGINEER YES 12 1 2 3 4 5 6 7 8 9 1 0 11 CH ON CH OFF Typical examples of external timer NO ...

Page 6: ... pressure falls below 0 5 this may indicate a leak on the central heating system Fig 2 Error Code E119 will be shown on the display 3 2 To Re Pressurise the System 1 The procedure is for the optional filling loop kit when fitted However even if your boiler has an external loop the principle is similar 2 Look at the boiler from underneath There will be two taps at the end of copper pipes one with a...

Page 7: ...arning labels on your boiler 6 Your boiler should have the following minimum clearances for Safety and Maintenance Fig 34 Top 200mm Bottom 200mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing 7 If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings 8 Flammable materials must not be stored in...

Page 8: ...E20 E28 E50 E125 E160 indicate faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 or E130 is displayed overheat of the primary water or flue system has occurred Turn the selector switch to the reset position and hold for at least 5 seconds If the boiler does not relight or the code is displayed regularly contact your instal...

Page 9: ... check online at www corgi gas safety com The boiler meets the requirements of Statutory Instrument The Boiler Efficiency Regulations 1993 No 3083 and is deemed to meet the requirements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0085 Product Production cer...

Page 10: ...c hot water will operate on demand To set the time of day Turn the timer outer bezel clockwise to align the pointer with the correct time to the nearest 15 minutes ensuring that A M P M is considered Do not at any time attempt to turn the bezel anti clockwise To set the timed heating program Decide which times of the day the central heating is required The heating will operate when the white tappe...

Page 11: ...ed until the fault has been corrected by a competent person Warning Gas Tap Heating Flow Heating Return and Mains Water Inlet Isolating Valves Fig 9 Fig 10 In an Emergency If a water or gas leak occurs or is suspected the boiler can be isolated at the inlet valves as follows 1 Using a suitable open ended spanner turn the square nut on the gas tap through 90 1 4 turn to isolate the gas supply at th...

Page 12: ... that you may need Our contact centre is open Monday to Friday 8am 6pm weekends and Bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling heateam it would be helpful if you could have the following information to hand 1 boiler serial number see opposite 2 boiler make and model number 3 Your installer name and address details 4 Proof of purchase if you do not have the boil...

Reviews: