background image

Description

Part Number

Blenheim Firefront (16 inch Fret)

Brass effect 

9800040

Antique (Black & Brass effect) 

9800075

Chrome effect 

9800076

Black Cast Iron with Brass Finials 

9800039

Blenheim Firefront (18 inch Fret)

Brass effect 

9800082

Antique (Black & Brass effect) 

9800083

Chrome effect 

9800084

Black Cast Iron with Brass Finials 

9800081

3. APPLIANCE DATA

This product uses fuel effect pieces containing Refractory Ceramic Fibres (RCF),
which are man-made vitreous silicate fibres. Excessive exposure to these materials
may cause irritation to eyes, skin and respiratory tract. Consequently, it is
important to take care when handling these articles to ensure that the release of
dust is kept to a minimum. To ensure that the release of fibres from these RCF
articles is kept to a minimum, during installation and servicing we recommend that
you use a HEPA filtered vacuum to remove any dust and soot accumulated in and
around the fire before and after working on the fire. When replacing these articles
we recommend that the replaced items are not broken up, but are sealed within a
heavy duty polythene bag, clearly labelled as RCF waste. RCF waste is classed as a
stable, non-reactive hazardous waste and may be disposed at a landfill licensed to
accept such waste. Protective clothing is not required when handling these articles,
but we recommend you follow the normal hygiene rules of not smoking, eating or
drinking in the work area and always wash your hands before eating or
drinking.This appliance does not contain any component manufactured from
asbestos or asbestos related products.

This appliance does not contain any components manufactured from asbestos or
asbestos related products.

There are no specific thermal efficiency requirements appropriate to this type of
appliance as they are intended for decorative purposes only. For the purposes of SAP the
efficiency is classed as 20% for use in the Space Heating Requirements calculation, see
Table 4a of SAP.

Page 6

INSTALLER GUIDE

© 

Baxi Heating U.K. Limited 2006.

Summary of Contents for 939

Page 1: ...i Fires Division Technical Helpline will be pleased to help Telephone 08706 061 065 National call rates apply in the United Kingdom In the Republic of Ireland Telephone 0044 8706 061 065 THIS APPLIANCE IS FOR USE WITH NATURAL GAS G20 WHEN CONVERTED USING CONVERSION KIT NO 0595211 THIS APPLIANCE IS FOR USE WITH PROPANE GAS G31 THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED KINGDOM G...

Page 2: ...mission to reproduce any part of this publication should be made giving details of the proposed use to the following address The Company Secretary Baxi Heating UK Limited Pentagon House Sir Frank Whittle Road Derby DE21 4XA Warning Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages Baxi Fires Division Erdingto...

Page 3: ...the British Standards Institute The Highest Standards Baxi Fires Division is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Baxi Fires Division is a CORGI registered company All our gas fires must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should not...

Page 4: ...staller Before continuing any further with the installation of this appliance please read the following guide to manual handling The lifting weight of this appliance DGF burner is 2 kg One person should be sufficient to lift the fire If for any reason this weight is considered too heavy then obtain assistance When lifting always keep your back straight Bend your legs and not your back Avoid twisti...

Page 5: ...cement Chair brick 0552301 Wonderfire models Wonderfire Gasflame 3 Convector box and 16inch Wonderfire Models Replacement Chair brick 0552311 Replacement Chair brick Trims Flat Brass effect 0552321 Flat Satin Chrome effect 0552331 Flat Black 0552341 Aspire trims with firefronts Satin Chrome effect 9820111 Brass effect 9820112 Black 9820113 Copper effect 9820114 Bauhaus Firefront 16 inch Fret Polis...

Page 6: ... and around the fire before and after working on the fire When replacing these articles we recommend that the replaced items are not broken up but are sealed within a heavy duty polythene bag clearly labelled as RCF waste RCF waste is classed as a stable non reactive hazardous waste and may be disposed at a landfill licensed to accept such waste Protective clothing is not required when handling th...

Page 7: ...ll relevant codes of practice The relevant parts of the current editions of the following British Standards BS 1251 BS EN 1856 Part 1 which replaces BS 4543 Part 2 BS 5440 Part 1 BS 5440 Part 2 BS 5871 Part 3 BS 6461 Part 1 BS 6891 BS 8303 Page 7 INSTALLER GUIDE Baxi Heating U K Limited 2006 Gas Natural G20 Propane G31 Inlet Pressure 20mbar 37mbar Input Max Gross 6 85kW 23 400 Btu h 6 7kW 22 860 B...

Page 8: ...g To a fireplace complete with surround and hearth as shown in figure 1 and complying with BS1251 For installations with the Spanish basket casting To a fireplace complete with surround and hearth as shown in figure 2 and complying with BS1251 For fireplace openings having dimensions different to those shown in figure 2 refer to Table 1 and BS 5871 Part 3 for flue sizes Into a fireplace that has a...

Page 9: ...INSTALLER GUIDE Baxi Heating U K Limited 2006 Figure 1 Hearth and fireplace opening See section 4 4 Figure 2 Hearth and fireplace opening for installations using the SPANISH BASKET CASTING ONLY See section 4 4 ...

Page 10: ...The flue must not be used for any other appliance or application Page 10 INSTALLER GUIDE Baxi Heating U K Limited 2006 Table 1 Flue sizing table ...

Page 11: ...panish basket casting It is recommended that a hearth should be installed as in figure 2 For installation with and without the Spanish basket casting If a hearth is not fitted or if a reduced depth hearth is fitted the fire must be installed so that the distance from the base of the fireplace opening in the wall to the finished floor level is at least 75mm Where there is no floor covering or carpe...

Page 12: ... soft wall coverings e g embossed vinyl etc are easily affected by heat They may scorch or become discoloured when close to a heating appliance Please bear this in mind when installing 4 9 This appliance must not be installed in any room that contains a bath or shower or where steam is regularly present 4 10 An extractor fan may only be used in the same room as this appliance or in any area from w...

Page 13: ...ctions greater than 75mm forward of the fixing plane of the fire are to be a minimum of 178mm from the fireplace opening See figure 4 4 14 2 Non combustible side projections to be 75mm from the fireplace opening See figure 4 4 15 The appliance is fitted with an A S D Atmosphere sensing device If the appliance closes down after a period of operation for no apparent reason the consumer should be inf...

Page 14: ...g screws 1 Inlet T connector elbow 1 Ceramic fuel effect pack 1 Burner tray trim Not fitted to Anthem or Quattro models Page 14 INSTALLER GUIDE Baxi Heating U K Limited 2006 Firefront Dimension X mm Dimension Y mm Azure 400 65 Quattro Anthem 390 65 Majestic 400 50 Portland 390 60 Figure 4 Appliance dimensions Firefront may differ from that shown ...

Page 15: ...ke exits from one terminal only and that the termination is suitable Observe where possible upstairs rooms and loft spaces for signs of escaping smoke indicating a defective flue If there is not a definite flow warm the flue for a few minutes and repeat the smoke pellet test If there is still no definite flow the flue may need remedial work Do not fit the appliance until there is a definite flow t...

Page 16: ...t protrude beyond the front plane of the fireplace opening by more than 33mm See figure 8 For installations with the Spanish Basket casting Place the casting centrally within the fireplace opening Position the casting to the rear of the opening Place the burner unit inside the casting It is important that the burner tray trim touches the inner front face of the casting This will give the customer ...

Page 17: ...previously Secure the burner to the front securing bracket using the screw removed previously 7 BURNER AND SUPPLY PIPE INSTALLATION A nut and olive is provided for an 8mm pipe inlet connection directly to the gas control The inlet T connector elbow can be rotated to allow a connection from any direction The inlet T connector includes a valve for isolating the gas supply Note that the centre of the...

Page 18: ...st the pilot ignition position The main burner should now light Depress the control knob slightly to release from the HIGH position and turn back clockwise to LOW While turning the burner flames should gradually become lower but remain alight Depress the control knob slightly to release from the LOW position and turn back clockwise to the Pilot ignition position The main burner should extinguish b...

Page 19: ...nd central to the appliance Quattro Anthem firefront only 1 The Quattro Anthem firefront is fitted with a set of fixing brackets Each bracket has two threaded holes As supplied the top threaded hole should be fitted with a 25mm long machine screw Remove the machine screw and locate to the threaded hole below 2 The screw should be set at a distance of 7mm Measured from the surface of the bracket to...

Page 20: ...he installer and owner guide for the ceramic fuel effect is supplied with the ceramic fuel effect It is important that the fitting guide for the ceramic fuel effect be placed inside or attached to this guide and handed to the customer following completion of the Final review section Page 20 INSTALLER GUIDE Baxi Heating U K Limited 2006 Figure 14 Hanging the firefront Figure 15 Lower ashpan locatio...

Page 21: ...ance and seek expert advice If the above test is satisfactory open all internal connecting doors hatches etc in the room Keep all doors and windows that open to the outside of the building closed Switch on any extractor fan installed in the same room as the appliance or a connecting room Open all doors and other openings between the fan and the appliance Recheck for spillage as above If the smoke ...

Page 22: ...plete clearance of the products of combustion with consequent health hazards Advise the customer how to operate the appliance Point out that lighting instruction details are contained within the owner guide Explain that this appliance is fitted with an atmosphere sensing device ODS pilot unit that will automatically shut off the supply of gas to the fire if for any reason the flames go out It will...

Page 23: ...d at a landfill licensed to accept such waste Protective clothing is not required when handling these articles but we recommend you follow the normal hygiene rules of not smoking eating or drinking in the work area and always wash your hands before eating or drinking Check that the appliance is clean and that soot or debris is not blocking the gaps between the ceramic fuel effect pieces causing an...

Page 24: ...trode tab 5 Remove the two screws securing the pilot unit See figure 18 6 Refit in the reverse order Note 1 The pilot unit is an atmosphere sensing device It must be replaced as a whole assembly Its individual components are not separately replaceable 11 4 To remove the gas valve See figure 19 1 Remove the burner unit See section 11 2 2 If lying the burner on its back ensure that the work surface ...

Page 25: ...he plug mark its position on the tap body 4 Remove the plug rotating slightly while pulling 5 Clean and grease the plug lightly with suitable grease Do not apply excessive grease Particularly make sure that the gas ports in the tap are not restricted by grease 6 Push the plug into the tap body and position the slot in line with the mark previously made on the tap body 7 Reassemble the niting head ...

Page 26: ...e 21 1 Remove the burner See section 11 7 2 Remove the burner clamping screw See figure 21 3 Unscrew the injector from the burner 4 Refit in the reverse order Page 26 INSTALLER GUIDE Baxi Heating U K Limited 2006 Figure 21 Main burner Injector removal ...

Reviews: