BAVARIA Owner’s manual
44
Caution
»
LPG lines must be inspected regularly, at least annually, and replaced if any deteriorati
-
on is found.
» If leakage is present, close the cylinder valve and have the system repaired before
further use. Gas system repairs should only be executed by a competent person.
» To be able to check the gas connections at the stove the front covers must be removed.
Danger
»
Do not smoke or use open flame while controlling for leakages.
»
Do not smoke or use open flame when replacing LPG cylinders.
» Do not use gas cylinders with damaged threads. Danger of gas leakage.
» Do not use grease or sealants at the valves.
Note: Gas system tightness test
With appliance valves closed!
» Open cylinder valve . close cylinder valve again
»
Wait until the manometer (in the pressurised line) has settled on a constant reading
» Observe the manometer for 3 minutes
» There is no leak if the pressure reading is constant - should the pressure drop, there is a
leak
Close the valve at the bottle, have the leak repaired - do not use the gas system, before
it has been repaired.
7.12.
Gas system main deck galley
(for notations see „7.12.2. Notation of the main decks gas system components“ page 45)
K
B
A
C
D
E
F
G
H
L