Installation
Mono Power Unit BUM 62, 63, 64
45
Baumüller Nürnberg GmbH
5.94005.12
y
ZK+, ZK-
DC link of further units if the total power of the input rectifier is not exceeded.
(max. 36 kW, see Technical Data, input rectifier).
If UL508C has to be observed:
Nominal tightening torque of the terminal screws: 4 Nm resp. 35,4
pound-inches.
y
1C1, 1D1
DC link of further units e.g. ballast.
If UL508C has to be observed:
Use 60°C / 75° C copper conductors only (UL508C, Nov 27, 1996,
Tab. 39.2). Nominal tightening torque of the terminal screws: 6 Nm resp. 53,1 pound-inches.
BUM 63:
M 8 terminals
BUM 64:
M 10 terminals