Is only valid for BM554X, BM555X, BM556X, accordingly the cooling versions S and A, for
BM557X cooling version -A:
Figure 88:
Connection fan BM557X-A
**
The power supply at X100 or X101 must externally be protected. At selection of the fuse
you must consider the cross-section of the connecting cable and the maximum allowable
load capacity (for X100: refer to X100 on
, for X101: refer to X101 on
).
In case you consider UL 508 C, you must limit the power supply to 100 W or fuse it with a
UL-listed 4 A fuse.
Ba- ... 1D1 Connections for brake resistor and DC link, refer to
on page 183 and the fol-
lowing
R
B
Brake resistor
PE....1W1
Power supply connection, refer to
on page 183 and the following
S1
Fuse (cable + device), refer to
S2
Fuse (fan) *)
S3
Fuses brake resistor circuit (required for BM557X, BM577X),
S4
Fuses DC link
L1
Power choke (not necessary for BM551X, BM5523; BM5524, BM5525 and
BM5XXX-X
R
/BM5XXX-X
S
/BM5XXX-X
W
)
L2
Mains filter
X2
Connections for ready-for-use, quick stop, pulse enable, refer to
X7/ENC
Encoder
X36
Connections for fans (only BM554X-S/-A, BM555X-S/-A, BM556X-S/-A, BM557X-A)
X100
Connections for 24 V power supply, additional data refer to
X101
Terminals for brake, motor temperature, refer to
on page 183 and the follow-
ing (SELV/PELV) and table X101 from
.
X300
Signal bus, connection to further devices, connected to the DC link,
connection of further devices without signal bus, refer to
.
BRA
Brake
PE....1W2
Connections for motor, refer to
on page 183 and the following.
Wiring diagrams