Installation
Instruction handbook
b maXX
5800
Document No. 5.16027.04
85
7
7.10 Installation procedure
h
Route all cables in an EMC-compatible manner.
h
Connect cables (refer to
(Observe the permissible torques!)
h
For all connections, attentions is to be paid to strain relief
The installation comprises the following steps:
1
Connect the motor through terminals 1U2, 1V2, 1W2 and PE.
Ensure the proper phases when connecting (rotational direction).
Observe the permissible torques!
2
Connect the DC link
,
refer to
3
Connect the protective ground conductor to the PE terminal (a fixed ground conductor
connection is absolutely mandatory).
4
Connect 24 V power supply:
BM58XX
via terminals
X200 -1, X200 -2.
5
Connect encoders (refer to
6
Connect the temperature sensor of the motor. (Observe the proper polarity!)
7
Connect the motor brake: (option)
DANGER!
Risk of fatal injury from electrical current!
Electrically live parts are life-threatening.
Therefore:
m
Make certain that the parts to be mounted (e.g. mains cables) and the mounting
areas are de-energized for the entire duration of mounting the device.
NOTICE!
The internal overload protection is activated at 200 % of the motor rated current (full
load current).
NOTE!
Plugging in and pulling out encoder cables while they are energized is prohibited, and
could lead to encoder destruction.
Therefore, always first switch off the 24 V supply voltage and lock the plug connectors
in place.