21
Advanced Timings for
8.3.4
GigE Vision
®
Message Channel
The following charts show some timings for the event signaling by the asynchronous
message channel. Vendor-specific events like "TriggerReady", "TriggerSkipped", "Trig
-
gerOverlapped" and "ReadoutActive" are explained.
8.3.4.1 TriggerReady
This event signals whether the camera is able to process incoming trigger signals or not.
Exposure
Readout
t
exposure(n)
t
readout(n+1)
t
readout(n)
t
exposure(n+1)
Trigger
TriggerReady
t
notready
8.3.4.2 TriggerSkipped
If the camera is unable to process incoming trigger signals, which means the camera
should be triggered within the interval t
notready
, these triggers are skipped. On Baumer Visi-
Line IP cameras the user will be informed about this fact by means of the event "Trigger-
Skipped".
Exposure
Readout
t
exposure(n)
t
readout(n+1)
t
readout(n)
t
exposure(n+1)
Trigger
TriggerReady
t
notready
TriggerSkipped
Summary of Contents for VisiLine