14
8.2 Field of View Position
The typical accuracy by assumption of the root mean square value is displayed in the
figure and the table below:
photosensitive
surface of the
sensor
cover glas
of sensor
thickness: D
front cover glass
thickness: 1 ± 0.1 mm
optical path
c-mount (17.526 mm)
0 5
0,5
± α
±XR
±YR
±XM
±YM
± Z
A
14,6
60,2
7,2
15,6
Camera
Type
± X
M
[mm]
± Y
M
[mm]
± X
R
[mm]
± Y
R
[mm]
± z
Zyp
[mm]
± α
typ
[°]
A
[mm]
D**
[mm]
VLG.I-02*
0.09
0.09
0.09
0.09
0.025
0.7
16.1
0.75
VLG.I-12*
0.06
0.06
0.06
0.06
0.025
0.7
16.6
0.5
VLG.I-20*
0.06
0.06
0.06
0.06
0.025
0.7
16.6
0.5
VLG.I-22*
0.07
0,07
0.07
0.07
0.025
0,5
16.2
0.55 ± 0.05
VLG.I-40*
0.07
0,07
0.07
0.07
0.025
0,5
16.2
0.55 ± 0.05
typical accuracy by assumption of the root mean square value
* C or M
** Dimension D in this table is from manufacturer datasheet (edition 06/2012)
Figure 8 ►