PA203

18

www.baumer.com

Second measured value

Requires manual entry in SCAL mode. In Teach mode, the value of 

the provided analog signal will be adopted.

Assigning the displayed value a second measured value

The value requires manual entry using the keypad.

4.3  Programming lock

To access programming line “Programming lock” at the end of the 

display configuration please proceed as follows:  

Enter value „dSP2“ h and hold   for 5 s. Enter character 0 or 1 at 

“LC”.

Programming lock disabled
Programming lock enabled

Programming lock means programming lines are read only which will 

be signaled by [dAtA] instead of [Pro] appearing in the display when 

accessing programming level.

Summary of Contents for PA203

Page 1: ...6 Configuration de l entrée 27 Configuration de l affichage 27 Verrouillage de la program 28 Caractéristiques techniques 29 Dimensions 30 Références de commande 30 Inhalt Seite Allgemeines Sicherheitshinweise 2 Beschreibung 4 Systembeschreibung 4 Anzeigenbereich 4 Gerät anschliessen 5 Anschlussbelegung 5 Ein und Ausgänge 5 Betriebsspannung anschl 5 Anschlussbeispiele 6 Bedienerebene Programmierebe...

Page 2: ...einwandfreiem Zustand verlassen Um diesen Geräte Status zu erhalten ist es erforderlich dass Sie das Gerät bestimmungsgemäss sicherheits und gefahrenbewusst unter Beachtung dieser Betriebsanleitung und insbesondere dieser Sicherheitshinweise installieren betreiben Stellen Sie sicher dass das Personal die Betriebsanleitung und hier besonders das Kapitel Sicherheitshinweise gelesen und verstan den h...

Page 3: ... Umweltschäden entstehen könnte n dann müssen entsprechende Sicherheitsvorkehrungen getroffen werden Manipulationen am Gerät können dessen Funktionssicherheit negativ beeinflussen und somit Gefahren hervorrufen Führen Sie keine Reparaturen am Gerät durch Schicken Sie defekte Geräte an den Hersteller zurück Installation Inbetriebnahme Bei Veränderungen einschliesslich des Betriebsverhaltens die die...

Page 4: ...wert Bei einem linearen Verhalten müssen zwei Mess inP bzw Anzeigewerte dSP definiert werden Um die be ste Präzision zu erreichen sollten diese 2 Punkte an beiden Enden des Anzeigebereiches gewählt werden Anzeige wert 2 Anzeige wert 1 Messwert 1 Messwert 2 Negative Steigung Die Koordinaten dieser 2 Punkte können direkt über die Tastatur eingegeben werden Tastatur Modus oder die anstehenden Mess we...

Page 5: ...ohlen bei HF Störung und falls bei grösseren Entfernungen Potential Ausgleichsleitungen installiert sind Die Sensor Anschlussleitungen sollen nicht im gleichen Kabelstrang mit der Netzversorgung und den Ausgangs Kontaktleitungen geführt werden 3 2 Ein und Ausgänge Messbereich Auflösung Eingangswiderstand 100 V 0 1 V 3 MΩ 600 V 0 1 V 3 MΩ 1 A 1 mA 14 mΩ 5 A 1 mA 14 mΩ Bei Wechselspannung AC maximal...

Page 6: ...e Es wird der aktuelle Wert ange zeigt Programmierebene Das Gerät wird mittels drei Tasten parametriert Diese befinden sich auf der unteren Seite des Frontrahmens Tastatur Sicht von unten Tastenfunktion Taste Dient zum Einstieg in die Programmierebene und zur Auswahl der Programmierzeile Taste Dient zur Funktionsauswahl oder Dekadenauswahl in der Program mierzeile Die jeweils angewählte Dekadenste...

Page 7: ...rammierzeilen können dann nur visualisiert aber nicht geändert werden Beim Einstieg in die Programmierebene erscheint dann dAtA anstelle von Pro 4 1 Eingangskonfiguration Auswahl Eingangsignal DC Strom oder Spannung AC Strom oder Spannung Spannung bis 600 V Spannung bis 100 V Strom bis 5 A Strom bis 1 A 4 2 Anzeigekonfiguration Anzeige Skalierungsmodus Tastatur Modus Teach Modus Erster Messwert Im...

Page 8: ...rt zugeordnet werden 4 3 Programmierung sperren Der Zutritt zur Programmierzeile Programmierung sperren erfolgt am Ende der Anzeigenkonfiguration wie folgt Nach Eingabe von dSP2 Taste 5 s gedrückt halten Ziffer 0 oder 1 bei LC eingeben Programmiersperre inaktiv Programmiersperre aktiv Wenn die Programmierung gesperrt ist können die Programmierzei len nur noch visualisiert aber nicht geändert werde...

Page 9: ...bare Messbereich Parameter Messeinheit Anzeigenbereich linearisierbar Dezimalpunkt Datenspeicherung 10 Jahre im EEPROM Auslegung Schutzklasse II DIN EN 61010 1 Überspannungskategorie II Verschmutzungsgrad 2 Störaussendung DIN EN 61000 6 3 Störfestigkeit DIN EN 61000 6 2 Technische Daten mechanisch Umgebungstemperatur 10 60 C Lagertemperatur 25 85 C Relative Luftfeuchte 95 nicht betauend Anschluss ...

Page 10: ...PA203 10 www baumer com 5 1 Abmessungen PA203 ohne Spannrahmen PA203 Spannrahmenmontage 6 Bestellbezeichnung PA203 00 AX01 Betriebsspannung 4 85 265 VAC und 100 300 VDC 5 21 53 VAC und 10 5 70 VDC ...

Page 11: ...neral Safety instructions 12 Description 14 System description 14 Display range 14 Connecting 15 Terminal assignment 15 Inputs and outputs 15 Voltage supply connection 15 Wiring examples 16 Operating mode Programming mode 17 Input configuration 18 Display configuration 18 Programming lock 19 Technical data 19 Dimensions 20 Part number 20 ...

Page 12: ...rate and in safe condition To keep the units in this condition it is necessary that the units be installed and operated properly in a safety and hazard conscious manner under observance of this operating manual and in particular of these safety precautions Make sure that the personnel has read and understood the operating manual and in particular the Safety Instructions chapter In addition to the ...

Page 13: ...life threatening danger health risks or a danger of property or environmental damage could result then appropriate safety precautions must be taken Tampering with the units can have a negative affect on their opera ting safety resulting in dangers Do not make repairs on the units Return defective units to the ma nufacturer Installation commissioning In case of changes including in the operating be...

Page 14: ... displayed value Linear behavior requires defining two measured values inP respectively displayed values dSP Both limits should be at the end of the display area to ensure maximum precision Displayed value 2 Displayed value 1 Measured value 1 Measured value 2 Linear decrease There are two options to enter the value coordinates Either by keypad in SCAL mode or using the teach in feature teach mode ...

Page 15: ...eld on one side Shields on both sides are recommen ded in case of RF interference or in case of equipotential bonding over long distances The sensor leads should not be in the same phase winding as the mains supply and the output contact leads 3 2 Inputs and outputs Measuring range Resolution Input resistance 100 V 0 1 V 3 MΩ 600 V 0 1 V 3 MΩ 1 A 1 mA 14 mΩ 5 A 1 mA 14 mΩ AC signals max 1 kHz 3 3 ...

Page 16: ... mode after the voltage supply has been turned on The current value is displayed Programing mode Device parameterization is by three soft keys located below the front panel see below Keypad view from below Key functions Key Access programming level and select programming line Key Select functionality or decade in the programming line The selected digit is flashing Key For incrementing of selected ...

Page 17: ...will be read only The device will signal any programming lock by dAtA instead of Pro upon access 4 1 Input configuration Selection input signal DC current or voltage AC current or voltage Voltage up to 600 V Voltage up to 100 V Current up to 5 A Current up to 1 A 4 2 Display configuration Scaling mode SCAL mode keypad mode Teach in mode First measured value Manual entry in SCAL mode In Teach mode ...

Page 18: ...l entry using the keypad 4 3 Programming lock To access programming line Programming lock at the end of the display configuration please proceed as follows Enter value dSP2 h and hold for 5 s Enter character 0 or 1 at LC Programming lock disabled Programming lock enabled Programming lock means programming lines are read only which will be signaled by dAtA instead of Pro appearing in the display wh...

Page 19: ...range parameters Measuring unit Display range can be linearised Decimal point Data memory 10 Jahre in EEPROM Standard Protection class II DIN EN 61010 1 Overvoltage category II Pollution degree 2 Emitted interference DIN EN 61000 6 3 Interference immunity DIN EN 61000 6 2 Technical data mechanical design Ambient temperature 10 60 C Storing temperature 25 85 C Relative humidity 95 non condensing Co...

Page 20: ...PA203 20 www baumer com 5 1 Dimensions PA203 without clip frame PA203 clip frame mounting 6 Part number PA203 00 AX01 Voltage supply 4 85 265 VAC and 100 300 VDC 5 21 53 VAC and 10 5 70 VDC ...

Page 21: ...aractéristiques principales 24 Plage d affichage 24 Raccorder l appareil 25 Raccordement des connecteurs 25 Entrées sorties 25 Alimentation 25 Exemples de raccordements 26 Mode consultation et programmation 26 Configuration de l entrée 27 Configuration de l affichage 27 Verrouillage de la programmation 28 Caractéristiques techniques 29 Dimensions 30 Références de commande 30 ...

Page 22: ...ueur L appareil a quitté l usine de production prêt à fonctionner et en parfait état technique vis à vis de la sécurité Afin de conserver cet état il est indispensable d installer et d utiliser l appareil conformément aux prescriptions en étant informé sur les règles de sécurité et les risques en respectant ce guide utilisateur et particulièrement les consignes de sécurité qu il contient Assurez v...

Page 23: ...entaux alors il faut prendre des mesures de sécurité correspondantes Des interventions dans l appareil peuvent avoir un effet négatif sur la sécurité de fonctionnement et par conséquent être dangereuses N effectuez aucune réparation sur l appareil Retournez l appareil dé fectueux au constructeur Installation Mise en service Suite à des modifications ou changement de comportement qui in fluencent l...

Page 24: ...obtenir une lecture dans l unité désirée Cela consiste à définir 2 points de mesure affichage afin d établir une relation proportionnelle entre la valeur du signal d entrée et la valeur d affichage Affichage 2 Affichage 1 Mesure 1 Mesure 2 Evolution négative Pour obtenir la meilleure précision ces 2 points doivent être choisis aux extrémités de l évolution du signal Les coordonnées de ces 2 points...

Page 25: ...t de relier le blindage à la terre d un coté Le raccorde ment du blindage aux deux extrémités est recommandé en milieu perturbé par des signaux HF ou pour des grandes longueurs de câbles à condition qu il existe une liaison équipotentielle 3 2 Entrées et sorties Signal Résolution Impédance 100 V 0 1 V 3 MΩ 600 V 0 1 V 3 MΩ 1 A 1 mA 14 mΩ 5 A 1 mA 14 mΩ Fréquence maxi de 1 kHz pour des signaux alte...

Page 26: ...ulte la valeur de la mesure Mode programmation La programmation de l indicateur s effectue par trois touches situées sous la face avant Clavier Vue de dessous Fonctions des touches Touche Permet l accès au mode programmation et le défilement des diffé rentes lignes à programmer Touche Permet suivant le cas la sélection d une option ou d un digit à mo difier dans une ligne de programmation Le digit...

Page 27: ...rentes lignes de configuration pour en vérifier le contenu Dans ce cas le message dAtA sera affiché à la place du message Pro en entrant en mode programmation 4 1 Configuration de l entrée Sélection du signal d entrée Courant ou tension DC Courant ou tension AC Tension jusqu à 600 V Tension jusqu à 100 V Courant jusqu à 5 A Courant jusqu à 1 A 4 2 Configuration de l affichage Configuration de l af...

Page 28: ... la programmation L accès à la ligne verrouillage de la programmation se fait à la fin de la configuration de l affichage comme suit Après avoir programmé la valeur dSP2 appuyer et maintenir la touche pendant 5 s Puis modifier LC à 0 ou 1 suivant le cas Verrouillage désactivé Verrouillage activé Lorsque la programmation est verrouillée il est toujours possible d accéder aux différentes lignes de c...

Page 29: ...ou tension Paramètres Echelle programmables Unité Linéarisation de la plage d affichage Point décimal Mémoire 10 ans par EEPROM Conformité Classe de protection II DIN EN 61010 1 Surtension catégorie II Degré de pollution 2 Emission DIN EN 61000 6 3 Immunité DIN EN 61000 6 2 Caractéristiques mécaniques Température ambiante 10 60 C Température de stockage 25 85 C Humidité relative 95 sans condensati...

Page 30: ...PA203 30 www baumer com 5 1 Dimensions PA203 Sans étrier PA203 Montage avec étrier 6 Références de commande PA203 00 AX01 Alimentation 4 85 265 VAC et 100 300 VDC 5 21 53 VAC et 10 5 70 VDC ...

Reviews: