PA203
www.baumer.com
17
How to program
1. Press , display will switch to [Pro] which means access to pro-
gramming level. Another press will make the display skip to first
programming line
(option input signal).
2. Proceed with line parameterization using keys , and
.
3. Pressing will save the parameters after having them indicated
for short. The device will automatically exit the programming level.
4. Programming access can be disabled at programming level, in this
case programming lines will be read only. The device will signal
any programming lock by [dAtA] instead of [Pro] upon access.
4.1 Input configuration
Selection input signal
DC current or voltage
AC current or voltage
Voltage up to 600 V
Voltage up to 100 V
Current up to 5 A
Current up to 1 A
4.2 Display configuration
Scaling mode
SCAL mode (keypad mode)
Teach-in mode
First measured value
Manual entry in SCAL mode.
In Teach mode, the value of the provided analog signal will be
adopted.
Assigning the first measured value a displayed value
Requires manual value entry and assignment using the keypad.
Admissible range:
DC: from –1999 to 9999
AC: 0 to 9999
Decimal point
Position of decimal point (related to dSP1).