ELECTRICAL CONNECTION / ACCESSORy - SENSOR CABLE AND MATING CONNECTOR

MB245EN - 11171693, 17A2, Baumer_PMG10-SSI_II_EN

 24/33

5.8.3.2 

For version with additional output

Mating connector M23, 17-pin with sensor cable HEK 17, 

17

 pins assigned (2x pow-

er supply, 1x internal shield, 10x signal, 4x data), female contacts, counter-clockwise 

(CCW)

 

i

 Suitable for first flange connector [C], see 

section 5.7.2.2

Cable length L 

Part number

 

3 m 

11172463

8

7

6

5

4

3

2

1

9

17

13

16

14

15

10

11

View 

X

X

PIN

WIRE 

COLOUR

WIRE CROSS- 

SECTION

ASSIGNMENT 

HMG10

1

Grey

AWG35

nE-

2

White/yellow

AWG35

DIR

3

Black

AWG35

SB*

4

Blue

AWG35

nE+

5

White/black

AWG35

PRE

6

Brown

AWG35

SA*

7

Brown/red

AWG21

+UB

8

Green/red

AWG31

C+

9

Green/black

AWG31

C _

10

Brown/blue

AWG21

11

2)

Black

AWG21

---

12

Red

AWG35

B+

13

Orange

AWG35

B-

14

Brown/yellow

AWG31

D+

15

Green

AWG35

A+

16

yellow

AWG35

A-

17

Brown/green

AWG31

D _

1)

  Only at version with speed switch

2)

  Internal shield, connected with all internal shields

Summary of Contents for Hubner Berlin PMG 10

Page 1: ...PMG 10 SSI Absolute encoder with magnetic sensing MB245EN 11171693 17A2 Baumer_PMG10 SSI_II_EN Installation and operating instructions...

Page 2: ...e B10 7 4 1 1 Mounting the spring disk coupling to the encoder 7 4 1 2 Mounting to drive shaft 7 4 1 3 Mounting the spring disk couling to drive shaft 8 4 2 Mounting with housing foot B3 9 4 2 1 Mount...

Page 3: ...connector C SSI with additional output 1 20 5 7 2 3 Second flange connector D Speed switch without additional output 2 21 5 7 2 4 Second flange connector D Speed switch with additional output 2 21 5 8...

Page 4: ...uting instruction The customer must check the suitability for the purpose intended Mounting and selection must be executed by authorized and qualified personnel Moun ting electrical commissioning or a...

Page 5: ...es or subsequent deliveries the data on the device type label must be quoted especially the type designation and the serial number 1 5 Approvals and warranty EU Declaration of Conformity meeting to th...

Page 6: ...parts can cause extremely serious injuries Before all work switch off all operating voltages and ensure machinery is statio nary Prevent reconnection operating voltages by third parties Risk of seriou...

Page 7: ...ified clearances and or angles are observed Risk of destruction due to mechanical shock Violent shocks e g due to hammer impacts can lead to the destruction of the sensing system Never use force Assem...

Page 8: ...shaft with key 4 Bearing shield 5 LED function indicators 6 Housing foot B3 Radial terminal boxes see section 5 A SSI additional output 1 B Speed switch additional output 2 Radial flange connectors s...

Page 9: ...ee section 5 page 13 3 3 Required tools not included in scope of delivery 2 5 mm 10 und 22 mm TX 10 TX 20 7 Spring disk coupling K 35 available as accessory see section 4 3 page 11 For mounting with E...

Page 10: ...other couplings are used pay attention to manufacturer s notes 4 1 2 Mounting to drive shaft Lifetime restrictions and angle error by radial deviations High runout of the drive shaft can cause encode...

Page 11: ...7 Mounting Mounting with EURO flange B10 MB245EN 11171693 17A2 Baumer_PMG10 SSI_II_EN 8 33 4 1 3 Mounting the spring disk couling to drive shaft Mt 2 3 Nm 2 5 mm...

Page 12: ...er couplings are used pay attention to manufacturer s notes 4 2 2 Mounting to drive shaft Lifetime restrictions and angle error by radial deviations High runout of the drive shaft can cause encoder an...

Page 13: ...6 7 Mounting Mounting with housing foot B3 MB245EN 11171693 17A2 Baumer_PMG10 SSI_II_EN 10 33 4 2 3 Mounting the housing foot and the spring disk coupling to drive shaft Mt 2 3 Nm 2 5 mm 90 mm 110 mm...

Page 14: ...ge B10 the same maximum permissible mounting tolerances are valid at version with housing foot B3 The encoder must be mounted on the drive with the least possible angular error and parallel misalignme...

Page 15: ...type coupling can damage the encoder Avoid blocking of both coupling halves claws pressed together The encoder shaft must not subjected to direct axial shock Use a depth gauge to find and observe the...

Page 16: ...ed R Zero pulse reference signal R_ Zero pulse inverted nE System OK error output nE_ System OK_ error output inverted PRE PRESET RESET DIR Rotating direction SP DSL_OUT1 speed switch Open Collector o...

Page 17: ...EN 11171693 17A2 Baumer_PMG10 SSI_II_EN 14 33 5 2 Data transfer SSI 5 3 Output signals incremental additional outputs Clock frequency 100 kHz 2 MHz Period T 0 5 10 s Time lag t1 0 25 5 s Monoflop time...

Page 18: ...INC2 Undervoltage OK additional output Overload incremental 2 Over temperature Status Internal error OK Speed Speed higher switching speed Speed lower switching speed overspeed 5 5 Speed switch Switc...

Page 19: ...erminal first terminal box A See section 5 6 2 1 or section 5 6 2 2 Connecting terminal second terminal box B See section 5 6 2 3 or section 5 6 2 4 5 6 Version with radial terminal boxes 5 6 1 Cable...

Page 20: ...A2 Baumer_PMG10 SSI_II_EN 5 6 2 Assignment connecting terminal Do not connect voltage supply to outputs Danger of damage Please beware of possible voltage drop in long cable leads inputs and out puts...

Page 21: ...nnection Version with radial terminal boxes MB245EN 11171693 17A2 Baumer_PMG10 SSI_II_EN 18 33 5 6 2 3 Connecting terminal second terminal box B Speed switch without additonal output 2 5 6 2 4 Connect...

Page 22: ...tection of the device the correct cable diameter must be used Connecting cables and mating connectors are not in scope of delivery and can be ordered separately as accessory see section 5 8 page 22 27...

Page 23: ...PRE 6 dnu SA 7 UB 8 C 9 C _ PIN ASSIGNMENT 10 11 Internal shield 12 dnu 13 dnu 14 D 15 dnu 16 dnu 17 D _ PIN ASSIGNMENT 10 11 Internal shield 12 B 13 B _ 14 D 15 A 16 A _ 17 D _ 5 7 2 Assignment flang...

Page 24: ...connector M23 male 12 pin clockwise 5 7 2 3 Second flange connector D Speed switch without additional output 2 5 7 2 4 Second flange connector D Speed switch with additional output 2 PIN ASSIGNMENT 1...

Page 25: ...cable length on request 5 8 2 Mating connector M23 i i Mating connectors are not in scope of delivery and can be ordered suitable to the ordered version of the encoder free of charge without connecti...

Page 26: ...i i Suitable for first flange connector C see section 5 7 2 1 Cable length L Part number 1 m 11172482 3 m 11172481 5 m 11172499 10 m 11172580 8 7 6 5 4 3 2 1 9 17 13 16 14 15 10 11 View X X PIN WIRE...

Page 27: ...ion 5 7 2 2 Cable length L Part number 3 m 11172463 8 7 6 5 4 3 2 1 9 17 13 16 14 15 10 11 View X X PIN WIRE COLOUR WIRE CROSS SECTION ASSIGNMENT HMG10 1 Grey AWG35 nE 2 White yellow AWG35 DIR 3 Black...

Page 28: ...with EURO flange B10 with radial terminal boxes Positive rotating direction A B Speed switch Additional output 2 SSI Additional output 1 6 2 Version with EURO flange B10 with radial flange connectors...

Page 29: ...11171693 17A2 Baumer_PMG10 SSI_II_EN 26 33 6 3 Version with housing foot B3 Positive rotating direction A B Speed switch Additional output 2 SSI Additional output 1 All dimensions in millimeters unle...

Page 30: ...7 6 8 Dismounting 27 33 MB245EN 11171693 17A2 Baumer_PMG10 SSI_II_EN 7 DISMOUNTING 7 1 Version with EURO flange B10 2 5 mm 2 5 mm 10 mm...

Page 31: ...10 11 6 7 7 Dismounting MB245EN 11171693 17A2 Baumer_PMG10 SSI_II_EN 28 33 7 2 Version with housing foot B3 2 5 mm 2 5 mm 10 mm...

Page 32: ...e TTL RS422 Sensing method Magnetic Code Gray default or binary Code sequence CW CCW programmable CW default Input signals SSI clock PRESET rotating direction Interference immunity EN 61000 6 2 Emitte...

Page 33: ...ertia 1 kgcm2 Admitted shaft load 450 N axial 650 N radial Materials Housing aluminium alloy Shaft stainless steel Operating temperature 40 85 C Relative humidity 95 non condensing Resistance IEC 6006...

Page 34: ...MB245EN 11171693 17A2 Baumer_PMG10 SSI_II_EN...

Page 35: ...MB245EN 11171693 17A2 Baumer_PMG10 SSI_II_EN...

Page 36: ...Berlin Germany Phone 49 0 30 69003 0 Fax 49 0 30 69003 104 info baumerhuebner com www baumer com motion MB245EN 11171693 17A2 22 03 2017 Baumer_PMG10 SSI_II_EN Original language of this instruction i...

Reviews: