background image

MB047 - 11055650

 Baumer_HOG12_II_DE-EN (18A1)  

 

 Table of contents 

Table of contents

1

 

General notes  

 ................................................................................................................................................................

2

2

 

Security indications  

 ..................................................................................................................................................

4

3

 

Preparation  

 .....................................................................................................................................................................

5

3.1

 

Scope of delivery  

 ............................................................................................................................................

5

3.2

 

Required for mounting (not included in scope of delivery)  

 .......................................................

5

3.3

 

Required tools (not included in scope of delivery)  

 ........................................................................

6

4

 

Mounting  

 ...........................................................................................................................................................................

6

4.1

 

Step 1  

 ...................................................................................................................................................................

6

4.2

 

Step 2  

 ...................................................................................................................................................................

7

4.3

 

Step 3  

 ...................................................................................................................................................................

8

4.4

 

Step 4  

 ...................................................................................................................................................................

8

4.5

 

Mounting instruction  

 .....................................................................................................................................

9

5

 

Dimension  

 ........................................................................................................................................................................

9

6

 

Electrical connection  

 ............................................................................................................................................

10

6.1

 

Terminal significance  

 .................................................................................................................................

10

6.2

 

Output signals  

 ...............................................................................................................................................

10

6.3

 

Connecting cable assignment  

 ...............................................................................................................

11

7

 

Dismounting  

 ................................................................................................................................................................

12

7.1

 

Step 1  

 ................................................................................................................................................................

12

7.2

 

Step 2  

 ................................................................................................................................................................

12

8

 

Technical data  

 ............................................................................................................................................................

14

8.1

 

Technical data - electrical ratings  

 .......................................................................................................

14

8.2

 

Technical data - mechanical design  

 ..................................................................................................

14

9

 

Accessories  

 .................................................................................................................................................................

15

Summary of Contents for Hubner Berlin HOG 12

Page 1: ...HOG 12 Inkrementaler Drehgeber Incremental encoder MB047 11055650 Baumer_HOG12_II_DE EN 18A1 Montage und Betriebsanleitung Mounting and operating instructions...

Page 2: ...rderliches Werkzeug nicht im Lieferumfang enthalten 6 4 Montage 6 4 1 Schritt 1 6 4 2 Schritt 2 7 4 3 Schritt 3 8 4 4 Schritt 4 8 4 5 Montagehinweis 9 5 Abmessung 9 6 Elektrischer Anschluss 10 6 1 Bes...

Page 3: ...uired tools not included in scope of delivery 6 4 Mounting 6 4 1 Step 1 6 4 2 Step 2 7 4 3 Step 3 8 4 4 Step 4 8 4 5 Mounting instruction 9 5 Dimension 9 6 Electrical connection 10 6 1 Terminal signif...

Page 4: ...urop ischen Richtlinien 1 7 Das Ger t ist zugelassen nach UL 1 8 Wir gew hren 2 Jahre Gew hrleistung im Rahmen der Bedingungen des Zentralverbandes der Elektroindustrie ZVEI 1 9 Wartungsarbeiten sind...

Page 5: ...ectives 1 7 The device is UL approved 1 8 We grant a 2 year warranty in accordance with the regulations of the ZVEI Central Association of the German Electrical Industry 1 9 Maintenance work is not ne...

Page 6: ...n Abst nde und oder Winkel unbedingt einhalten 2 4 Zerst rungsgefahr durch mechanischen Schock Starke Ersch tterungen z B Hammerschl ge k nnen zur Zerst rung der Abtastung f hren Niemals Gewalt anwend...

Page 7: ...ntial that the specified clearances and or angles are observed 2 4 Risk of destruction due to mechanical shock Violent shocks e g due to hammer impacts can lead to the destruction of the sensing syste...

Page 8: ...g ring 4 Torx screw M3x12 mm 5 Torque sheet 6 Connecting cable see section 6 3 length 1 m 3 Vorbereitung 3 1 Lieferumfang 3 Preparation 3 1 Scope of delivery 3 Vorbereitung Preparation 3 2 Zur Montage...

Page 9: ...4 Mounting 4 1 Step 1 3 3 Erforderliches Werkzeug nicht im Lieferumfang enthalten 3 3 Required tools not included in scope of delivery 4 3 Siehe Seite 5 See page 5 2 5 mm TX 10 9 Werkzeugset als Zube...

Page 10: ...e einen m glichst kleinen Rundlauffehler aufweisen da dieser zu einem Winkelfehler f hren kann Rundlauffehler verursachen Vibrati onen die die Lebensdauer des Ger tes verk rzen k nnen The drive shaft...

Page 11: ...DE EN 18A1 8 Montage Mounting 4 4 3 Schritt 3 4 3 Step 3 4 4 Schritt 4 4 4 Step 4 Zul Anzugsmoment Max tightening torque Mt 2 3 Nm Anschlusskabel siehe Abschnitt 6 3 Connecting cable see section 6 3 4...

Page 12: ...Montagehinweis 4 5 Mounting instruction i Wir empfehlen das Ger t so zu montieren dass der Kabelanschluss keinem direkten Wassereintritt ausgesetzt ist i It is recommended to mount the device with cab...

Page 13: ...UB Betriebsspannung Voltage supply GND 0V Masseanschluss Ground Erdungsanschluss Geh use Earth ground housing K1 A A Ausgangssignal Kanal 1 Output signal channel 1 K1 A A Ausgangssignal Kanal 1 invert...

Page 14: ...B Wei White K1 Braun Brown K1 Gr n Green K2 Grau Grey K0 Rosa Pink K0 Gelb Yellow K2 Blau Blue Betriebsspannung nicht auf Ausg nge legen Zerst rungsgefahr Spannungsabf lle in langen Leitungen ber cksi...

Page 15: ...MB047 11055650 Baumer_HOG12_II_DE EN 18A1 12 7 2 Schritt 2 7 2 Step 2 7 Demontage 7 1 Schritt 1 7 Dismounting 7 1 Step 1 Demontage Dismounting 7 4 5 8 7 Siehe Seite 5 See page 5 2 5 mm TX 10...

Page 16: ...stufen HTL TTL RS422 je nach Bestellung St rfestigkeit EN 61000 6 2 St raussendung EN 61000 6 3 Zulassungen CE UL Zulassung E256710 8 2 Technische Daten mechanisch Baugr e Flansch 125 mm Wellenart 30...

Page 17: ...TTL RS422 as ordered Interference immunity EN 61000 6 2 Emitted interference EN 61000 6 3 Approvals CE UL approval E256710 8 2 Technical data mechanical design Size flange 125 mm Shaft type 30 45 mm...

Page 18: ...links HEAG 171 HEAG 176 Digital speed switch DS 93 Tool kit order number 11068265 Analyzer for encoders HENQ 1100 9 Zubeh r Digital Konverter HEAG 151 HEAG 154 LWL bertrager HEAG 171 HEAG 176 Digitale...

Page 19: ...MB047 11055650 Baumer_HOG12_II_DE EN 18A1...

Page 20: ...H P O Box 12 69 43 10609 Berlin Germany Phone 49 0 30 69003 0 Fax 49 0 30 69003 104 info baumerhuebner com www baumer com motion Originalsprache der Anleitung ist Deutsch Technische nderungen vorbehal...

Reviews: