35
Baumer_HOG11-FSL-T2_II_DE-EN (16A2)
MB072.1T2 - 11070663
9
Technical data
* The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
9
Technical data
9.1
Technical data - electrical ratings
•
Interference immunity:
EN 61000-6-2:2005
•
Emitted interference:
EN 61000-6-3:2007/A1:2011
•
Approval: CE
9.2
Technical data - electrical ratings (encoder)
•
Voltage supply:
9...30 VDC * (HTL-P, TTL - Version R)
5 VDC ±5 % (TTL)
•
Consumption w/o load:
≤100 mA
•
Pulses per revolution:
300...5000 (As ordered)
•
Phase shift:
90° ±20°
•
Duty cycle:
40...60 %
•
Reference signal:
Zero pulse, width 90°
•
Output frequency:
≤120 kHz
≤300 kHz option
•
Output signals:
K1, K2, K0 + inverted
Error output (only EMS)
•
Output stages:
HTL-P (power linedriver)
TTL/RS422
(As ordered)
•
Sensing method:
Optical
9.3
Technical data - electrical ratings (centrifugal switch)
•
Switching accuracy:
±4 % (Δn = 2 rpm/s)
≤ +20 % (Δn = 1500 rpm/s)
•
Switching deviation cw-ccw rotation:
≤3 %
•
Switching hysteresis:
~40 % of switching speed
•
Switching outputs:
1 output, speed control
•
Output switching capacity:
≤6 A / 230 VAC
≤1 A / 125 VDC
•
Minimum switching current:
50 mA