![Baumer Clever Level LBFH Operating Instructions Manual Download Page 12](http://html.mh-extra.com/html/baumer/clever-level-lbfh/clever-level-lbfh_operating-instructions-manual_2710700012.webp)
Operating Instructions
Level measurement
CleverLevel
®
LBFH/I
Point level detection – hygienic/industrial
14.3 Factory settings and user settings
LED function
SW1*
SW2*
LED indicator
User-defined meaning
0
0
Green
1
0
Yellow
0
1
Blue
1
1
Blue
Error
Error
Flashing red
Short circuit Short circuit
Red
*1 = active, 0 = inactive
Sensor parameter
Factory setting
User setting
SW1
(NO)
Switch window,
min.
0%
Switch window,
max.
75.3%
Switch window
hysteresis
2.4%
Damping
0.1 s
Sensor parameter
Factory setting
User setting
SW2
(NC)
Switch window,
min.
0%
Switch window,
max.
75.3%
Switch window
hysteresis
2.4%
Damping
0.1 s
With the factory settings the switch outputs switch complementarily. This corresponds to the switching
characteristics of the LBFS.
Configuration via qTeach is enabled in the factory settings and can be disabled by the user.
12 / 33
www.baumer.com