![Baumer Clever Level LBFH Operating Instructions Manual Download Page 10](http://html.mh-extra.com/html/baumer/clever-level-lbfh/clever-level-lbfh_operating-instructions-manual_2710700010.webp)
Operating Instructions
Level measurement
CleverLevel
®
LBFH/I
Point level detection – hygienic/industrial
11. Disposal
f
Do not dispose of in household
waste.
f
Separate materials and dispose
of in compliance with nationally
applicable regulations.
12. Accessories
For adapter and other accessories see www.baumer.com.
13. Technical data
Environmental conditions
Features
Operating temperature
range
-40 ... -85 °C
Repeatability
± 1 mm
Storage temperature range
-40 ... -85 °C
Hysteresis
± 1 mm
Ambient humidity
< 98 % RH,
condensing
Response time
0.02 s type.
Protection class
IP67
IP69K (with
appropriate cable)
Damping
0.1 ... 10.0 s (adjustable)
Oscillations (sinusoidal)
(EN 60068-2-6)
1.6 mm p-p
(2 ... 25 Hz),
4 g (25 ...100 Hz),
1 octave / min.
Power supply
Output signal
Voltage supply range
8 ... 36 V DC
Output type
PNP
NPN
Digital (push-pull)
Reverse polarity protec-
tion
yes
Current load
100 mA max.
Current consumption
(without load)
25 mA type.,
50 mA max.
Short circuit protec-
tion
yes
Acceleration time
< 3 s
Voltage drop
PNP: (+Vs -0.5 V) ± 0.2 V,
Rload = 10 kΩ
NPN: (+0.5 V) ± 0.5 V,
Rload = 10 kΩ
Leakage current
± 100 μA max.
Switching logic
Normally open (NO), active
low
Normally closed (NC), high
enabled
10 / 33